Wuxi Guanya Refrigeration Technology co., ltd

What Should Be Noticed In Detail When Installing A Precision Chiller?

First, when installation, everyone needs to check whether your cold water machine works normal, whether the accessories are all right, whether there is damage, so as to avoid problems in installation.

Second, when installing, the site of the precision chiller must be a place where the balance can support the weight of the machine. Once the weight of the machine can not be borne, heap of the heap matters are behind.

Third. The environment of the precision chiller should be in the room at a temperature above 5 centigrade. There should be enough space around the precision chiller for the maintenance of the machine.

Fourth. When selecting the precision chiller, one end of the chiller should leave the tube space for the condenser, and of course, use the door or other locations.

Fifth, to determine the application of your precision chiller, the greater operation power of the chiller and the water flow rate of the evaporator and condenser should be clearly calculated.

Sixth, we must consider any special circumstances to ensure that the water flow of the precision chiller is stable.

Seventh. The pipeline design of the precision chiller should be carried out in accordance with the conventional method. In the piping, the elasticity of the pipe should be set up and the water of the evaporator should be removed.

Eighth, it is suggested that the water supply of the evaporator and condenser choose water of better quality. Once the water quality is not good, it will cause certain grime, which will affect the heat transfer and breed the microorganism bacteria, and increase the operation and maintenance cost of the machine.

Nine, the filters for water pipes should be cleaned regularly, and all interfaces should be treated with rust prevention.
Related News
Related Products
  • Water Cooled Chiller

    Water Cooled Chiller

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • Low Temperature Chiller

    Low Temperature Chiller

    April 10, 2018Low Temperature Cooling Chiller LT model: LT-5018N,LT-5040N,LT-5062N,LT-5090N,LT-50A1N,LT-50A2N; Medium Temperature Range: -45℃~30℃. ASET multifunctional controller, control outlet temperature of water tankview
  • Wafer Test Chiller

    Wafer Test Chiller

    February 28, 2019-45℃~+200℃ 2.5kW~25kW ±0.3℃view
  • Chip Test Heating Cooling System

    Chip Test Heating Cooling System

    February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view