LNEYA Low temperature thermostatic bath instructions
Low temperature thermostat is widely used in petroleum, chemical industry, electronic instruments, physical, chemical and biological engineering, medicine and health, life sciences, food industry, physical testing and chemical analysis and research departments, universities, enterprises and production quality inspection departments, for the user to work to provide a heat source temperature field controlled, uniform and constant constant temperature test, or test on the test samples or products, but also can be used as direct heating or cooling and heating or cooling cooling or heating.
Low temperature thermostatic bath is widely used to provide a user with a controlled and uniform temperature field source, a constant temperature test for a test sample or a produced product be used as a heat source or cold source for direct heating or cooling or auxiliary heating or cooling.
1. The liquid medium must be added first in the low temperature or constant temperature bath before using, otherwise, the heater will be damaged when the electricity is working. The liquid surface of the medium should be lower 30mm than the working plate.
2. The selection of liquid medium in low temperature and constant temperature bath should be in accordance with the following principles:
3. When the working temperature is at 5℃~85 ℃, choose water as the liquid medium.
4. When the working temperature is at 85℃~95 ℃, choose 15% glycerol solution as the liquid medium.
5. When the working temperature is below 5 centigrade, choose alcohol or frozen liquid as the liquid medium.
6. When the cryogenic thermostat switch is closed, the refrigeration switch should be opened for a 10~20 minutes interval (depending on the ambient temperature).
7. Low temperature constant temperature bath power: 220V50Hz, the power of the power supply should be greater than the total power of the instrument. The power supply must have a good “grounding” device.
8. The low temperature and constant temperature bath should be placed in the dry and ventilated place, and there are no obstacles in the 300mm around the instrument. When low temperature and constant temperature bath temperature is low, don’t put hands into the slot, in order to prevent frost injury. After using, all switches should be closed and the cut the power off. Clean the Low Temperature Thermostat Bath frequently and keep the work table and the operation panel clean.

Related recommendations
-
Factors affecting the cooling capacity of the chiller of the chemical reactor cooling system
1437There are various types of chillers, such as air-cooled chillers, water-cooled chillers, etc. But no matter what the chiller is, there are some factors that affect the cooling capacity of the chiller. A cooler is an energy-saving device that is co...
View details -
Clean of Ultra-low Temperature Freezer
927Cleanenvironment of ultra-lowtemperature freezer: Once a monthClean up all ground debris and dust with sanitary ware, reduce dust adsorption in compressor and refrigeration system, affect heat dissipationPrevent dust from adsorbing on circuit boar...
View details -
Manufacturer explains what are the influences of the oil level and oil difference of the chiller?
1208The chiller manufacturer tells everyone that in addition to the refrigeration system, the lubricating oil system is also an important part, with its own oil reservoir and special oil cooler. Therefore, we must understand the influence of the oil l...
View details -
All analysis of refrigerant changing process of industrial chiller unit
1046Refrigerant is an indispensable part of the refrigeration system of the industrial chiller. During the operation of the industrial refrigeration unit, the refrigerant constantly changes in the industrial refrigeration unit to achieve the cooling e...
View details