Talk about the main points of choice for circulating water chiller in laboratory
Circulating water cooler is also called chiller. It is a kind of cooling water equipment that can provide constant temperature, constant flow and constant pressure. Currently there are many kinds of chillers in the market. How to buy a suitable chiller for the laboratory?
Circulating water coolers are divided into two types, air-cooled and water-cooled, according to the condensation method, and water-cooled usually requires a matching cooling tower or water tank, and special water inlet and drainage are required, which requires relatively high laboratory hardware facilities, so we only Discuss the laboratory circulating water cooler here.
Generally, you can choose from the following aspects:
1. Compressor: The cost of the compressor alone accounts for a large part of the cost of the chiller, and also determines the cooling capacity, so it is the core component. You can usually choose from four aspects: brand, stability, energy consumption and service life. 2. Components: relays, thermal protectors, expansion valves, pressure controllers, etc. The quality of small components determines the reliability of the chiller.


Lneya’s FL-800N is a circulating water cooler specially developed for the laboratory, temperature range: -15°C~30°C, ASET multi-function controller, water tank temperature control, customizable temperature control accuracy ±0.5℃ . When the temperature is 20℃, the cooling capacity is 0.9 kilowatts; when the temperature is 10℃, the cooling capacity is 0.76 kilowatts; when the temperature is -10℃, the cooling capacity is 0.35 kilowatts. The refrigerant is R404A (optional R448), and the external dimensions are 415*225*497 (mm).

The fully enclosed circulation system can effectively prevent the evaporation and pollution of the heat transfer medium and save resources. It is widely used in low-temperature conditions that require chemical, biological, and physical experiments at low temperatures. It can be combined with rotary evaporator, glass reactor and other instruments to carry out various chemical reactions. The FL-800N circulating water cooler will go through 24 hours of uninterrupted testing in the workshop before it is sent to the customer to ensure that the customer does not have hidden dangers before using the equipment.

Related recommendations
-
-
The ethylene glycol chiller solution is too cold and too hot
1126When the ethylene glycol chiller solutionis overheated and overcooled during operation, if you don't understand theseconditions well, you will not be able to operate the equipment well.The supercooling phenomenon of the solutionof the glycol ch...
View details -
LNEYA chip test temperature control system operation overview
1446With the development of technology, chip testing has a very high requirement for its accuracy under certain temperature requirements. So what is the understanding of the chip test system? Chip testing requires high temperature accuracy in low temp...
View details -
Scanning Electron Microscope Cooling Water Circulation System
1138Scanning Electron Microscope (SEM) is a high-resolution microscope widely used in materials science, biology, nanotechnology and other fields. SEM generates a certain amount of heat during operation. In order to ensure the stable operation and...
View details