Wuxi Guanya Refrigeration Technology co., ltd

Effect Of Humidity On Laboratory Chillers

The high humidity reduces the insulation strength of the electrical equipment of the chiller in the laboratory. The moisture in the air adheres to the surface of the insulating material to form condensation, which reduces the insulation resistance of the electrical equipment, and the leakage current of the equipment is greatly increased, resulting in insulation breakdown. Condensation inside the switchgear causes creepage and flashover accidents, resulting in electrical faults.

If the air is not convective, the mold growth will increase rapidly. Therefore, in the case of the same humidity and the same temperature, the indoor equipment is much more severe than the outdoor equipment. The chiller material in the laboratory itself or the surface is dirty, which provides the necessary nutrients for the growth of mold. After the mold is formed, the mold cells contain a large amount of water. When the hyphae are meshed with the surface of the insulator, not only the insulation performance of the product is greatly reduced, but also the appearance and signs of the device are affected. Molds often secrete acidic substances during the metabolism process. The conductive metal and the electrical contact material are caused to form a dark film, resulting in an increase in contact resistance. Especially for the printed circuit board of the chiller of laboratory in Wuxi Guanya LNEYA Constant Temperature Refrigeration Technology Co., Ltd., if it is in such an environment for a long time, it will corrode the circuit, which will reduce the accuracy of the instrument, or cause equipment failure or even burn the instrument.

After the conductive metal and magnetic conductive silicon steel sheet in the electrical equipment are corroded, the performance and service life of the equipment will be seriously reduced. After the relative humidity reaches a certain value, the corrosion of the metal in the test room special test system will suddenly increase. Corrosion causes the metal to lose its proper properties. The heat exchanger of the electrical cabinet isolates the air inside and outside the control box to ensure the air inside the box is clean. It adopts the heat pipe structure design, has high heat exchange capacity, simple structure and convenient maintenance.

The chiller for laboratory use is not used for general temperature control systems. The effect of humidity on its laboratory chiller is relatively large. Therefore, we try to avoid the influence of humidity on the chiller in the laboratory and place it in a special environment.


Related News
Related Products
  • Water Cooled Chiller

    Water Cooled Chiller

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • High-Low Temperature Test Chamber

    High-Low Temperature Test Chamber

    March 30, 2018Performance characteristics:1. In the refrigeration system, the condensation adopts air cooling mode, which has a wide temperature control range, which can meet the user's various needs.2. With a unique b...view
  • Humidity Test Chamber

    Humidity Test Chamber

    April 8, 2018Performance characteristics: 1. With wide temperature control range, can meet the user's various needs.2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control canview
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • Small Gas Condensing System

    Small Gas Condensing System

    April 10, 2018ModelHQ-0540HQ-1040HQ-2540HQ-5040HQ-0575WHQ-1075WHQ-2575WHQ-5075WGas flow5m3/h10m3/h25m3/h50m3/h5m3/h10m3/h25m3/h50m3/hLowest Temp.-40℃-40℃-40℃-40℃-75℃-75℃-75℃-75℃Primary Temp.There is no-20℃...view
products
Contact
Tel: + 86 18751547965
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat