Leakage Detection Tips of Low Temperature Freezer
Pressure leaking detection
It is an effective way to check and find out the leakage point. The leakage detecting pressure of refrigerating system of freezer is relevant to the type of refrigerating fluid and cooling and the location of tube. The leakage detecting pressure of high-pressure system is 1.25 times greater than designing condensing pressure, while that of the low-pressure system is near 1.2 times higher than saturation pressure in condition of the temperature in summer. With it, refrigerating plant can stop from leakage no matter it is working or parking. Some cooling system should be detected according to the provisions of the pressure if there is a predefined acceptance or leakage detection standard. Obviously, the leakage detecting pressure can not be raised casually, otherwise it is likely to destroy the equipment, resulting in an accident.
Bubble test
It is a widely used detecting method at present , especially for those medium and large freezer systems that take advantage of it to search for the leak point. Generally, bubble test is comprised of soap or soap powder. The solution of soapy water should not be too ropy; if not, the viscosity will be too big to flow, worsening the sensitiveness of the test. But as an editor of Whose Low Temperature Freezer Is Best,i would like to tell you that the modulation not ought to be too dilute, or else the fluidity will be too large to be adhere to the surface of the equipment, being hard to form the bubbles. The soapy water can be applied the leaky point with hairbrush directly to observe whether this position is blistering. When it comes to the positions that are difficult to observe straightway, mirror reflection and flashlight can be used. After the test, the soapy water should be dried up in case of corrosion.
LNEYA have more freezers for sale and low temperature freezer price is really affordable.
Related recommendations
-
Wafer thin film deposition temperature control equipment chiller usage environment
1025Usage environment for wafer thin film deposition cooling chiller
View details -
Semiconductor heating and cooling thermostat compressor fault detection instructions
805In the semiconductor heating and cooling thermostat, the compressor is one of its core components. Once it fails, it will affect the operation of the whole system. How to solve the fault is better? The faults of semiconductor heating and cooling t...
View details -
How To Vacuum The Ultra-Low Temperature Freezer Refrigeration System?
1072LNEYA ultra-low temperature freezer indoor and outdoor connection has been completed, observe the oil pump oil mark indication to see if there is enough oil, and then start the vacuum pump to see if it is normal. Then unscrew the large valve back ...
View details -
Is the choice of a centrifugal pump or a volumetric pump in a pharmaceutical laboratory?
1315Performance: In order to be able to select the type of pump that is suitable in the pharmaceutical laboratory, it is necessary to have a deep understanding of its performance and understand the difference in its specific working principle. To this...
View details