Maintenance principle of fluorinated liquid TCU temperature control system
The working environment of the fluorinated liquid TCU temperature control system

Fluorinated liquid TCU temperature control system should be placed in a ventilated, dry and clean place;
(2) The distance between the fluorinated liquid TCU temperature control system and the partition is greater than 1m;
(3) The louver holes on both sides of the fluorinated liquid TCU temperature control system must not be obstructed or blocked
- After each use of the fluorinated liquid TCU temperature control system, it is necessary to wipe all kinds of stains, oils and solvents on the surface of the machine with a soft cloth to keep it clean;
3. If the fluorinated liquid TCU temperature control system has been used for more than six months, or the high/low pressure switch often fails, or the cooling capacity is reduced, the condenser needs to be cleaned;
4. If it is not an emergency, it is not allowed to close the fluorinated liquid TCU temperature control system by cutting off the main power supply; if the fluorinated liquid TCU temperature control system is not used for a long time in winter, first close the fluorinated liquid TCU temperature control system, and then close the main power supply. And drain the water in the system;
5. Try not to tighten the interface of the fluorinated liquid TCU temperature control system too tightly, and keep regular activities to avoid being locked;
6. Pay attention to observe the condition of the heat transfer oil in the TCU temperature control system of the fluorinated liquid. If there is any color change, you need to contact the heat transfer oil manufacturer;
7. When maintaining the TCU temperature control system of fluorinated liquid, it is necessary to purchase qualified accessories, and do not replace them at will, so as not to cause a fatal blow to the machine.


Email: sales@cnzlj.com
WhatsApp: 086 13912479193
Related recommendations
-
Common Failures of Salt Spray Environmental Chambers
1663When you encounter some common failures of salt spray environmental chambers, how to solve them? Wuxi Guanya Refrigeration Technology Co., Ltd. has brought the relevant fault tips as follows.Salt spray environmental chamber cannot sprayFailure cau...
View details -
Low-temperature refrigerator manufacturers’ energy adjustment instructions
1391The energy regulation of low-temperature refrigerator manufacturers' equipment during operation is also very important. In order to adapt to the change of energy load, Wuxi Guanya (LNEYA) low-temperature refrigerator manufacturers should pay atten...
View details -
Cooling simulation system for battery pack extreme performance test
1703With the development of technology, pure electric vehicles are becoming more and more common, but pure electric vehicles are difficult to get a better solution in terms of cruising range, charging speed, and pollution after battery waste. This mak...
View details -
Where can industrial heating circulators be useful?
1842The industrial heating circulator can provide a circulation device of cold source and heat source, and has a wide working range. It is used in the pharmaceutical, chemical, biological and other industries to provide heat and cold sources for reac...
View details
LNEYA Industrial Chillers Manufacturer Supplier