Influence of refrigeration factors on high temperature enclosed explosion-proof industrial chillers
Check whether the high and low temperature enclosed explosion-proof industrial chiller is the cause of its own failure. The selection must be accurate. If the model is not in place, the required refrigeration effect will also not be achieved. It is recommended that the user purchase the required refrigeration capacity Such parameters are provided to the chiller manufacturer, and the professional selection is made to achieve the required refrigeration effect.
Envirnmental factor:
The high temperature enclosed explosion-proof industrial chiller has higher requirements for the working environment, because it is cooled by hot air circulation. If the ventilation effect of the installation workshop is not good, it will directly affect the cooling effect. There is more dust on the surface of the compressor, which leads to slow heat dissipation of the compressor, which indirectly affects the cooling effect. The refrigerant leaks or is insufficient, resulting in a decrease in the cooling effect of the chiller. The accumulation of debris or sludge in the evaporator causes the flow rate to slow down, which affects the evaporation and condensation capacity and reduces the cooling effect.
Factors affecting the cooling effect of equipment:
High-temperature enclosed explosion-proof industrial chiller condenser dust affects the heat dissipation effect. The equipped unit is operating at full load, and the ambient temperature rises, resulting in insufficient cooling power and thus affecting the cooling effect.
Insufficient refrigerant, which is what we often call Freon, will also lead to poor refrigeration performance of high-temperature enclosed explosion-proof industrial chillers. During the operation of the chiller, the liquid refrigerant in the evaporator continuously absorbs heat from the water and begins to evaporate. After the compressor is compressed and the expansion valve is throttled, it becomes a low-temperature and low-pressure refrigerant and enters the evaporator to continue. Circulation, if the use time is too long, the refrigerant will volatilize, which will affect the refrigeration effect.
Summarize
When the filter of the chiller is blocked, it will affect the heat exchange effect of the condenser, and the cooling effect of the whole machine is not good. It is necessary to check regularly and clean the filter.
Related recommendations
-
Semiconductor refrigeration temperature control system selection instructions
1415The choice of semiconductor refrigeration temperature control system should be based on the cold load and what to use for consideration. For refrigeration systems with long operating conditions with low load operation, it is suitable to select mul...
View details -
200L crystallization dissolution kettle cooling and heating system
855For the needs of 200L crystallization dissolution kettle cooling and heating system applications, this type of equipment is usually used in the crystallization, dissolution and other processes in the fields of chemical industry, pharmace...
View details -
Install a refrigeration unit for the circulating cooling water of the quenching tank
1102The quenching tank is a container filled with quenching medium. When the workpiece is immersed in the tank for cooling, it must be able to ensure that the workpiece is uniformly quenched at a reasonable cooling rate. It is a container that provide...
View details -
Motor test chiller compressor causes wear
1096Motor testing chiller oil quality may be one of the main reasons affecting crankshaft wear. If the engine oil is used in the chiller refrigeration system, the engine oil that does not meet the requirements and is of poor quality may cause cranksha...
View details