Precautions for safe use of heat transfer oil temperature control equipment
With the extensive use of thermal oil temperature control equipment, the safe use of thermal oil temperature control equipment is a concern for users. For manufacturers, it is very important to share the precautions for the use of thermal oil temperature control equipment.
For users of thermal oil temperature control equipment, the fire protection of these electric heating equipment is very important. Firstly, analyze the cause of the general fire in the electric heating equipment. Place the electric heater that is energized near the flammable or inflammable material, and cause a fire under the high temperature baking for a long time. The electric heater is not equipped with a plug, and the electric wire head is directly inserted into the socket, so that a short circuit may occur and a fire may occur. The user of the heat-conducting oil temperature control device does not remove the plug of the electric heater when leaving, and the time is too long, causing the electric heater to overheat and igniting the adjacent combustible material to cause a fire. The heat-conducting oil temperature control equipment heating wire is used after repeated repairs, which may cause the line to be overloaded and cause a fire. It is worth noting that the heating wire of the heat-conducting oil temperature control device is made of nickel or chrome alloy. Since the power of the electric heater is relatively large, the user may accidentally ignore the safety, and the fire may occur at any time.
In order to prevent the heat conduction oil temperature control equipment from catching fire, the wire must be installed with a plug. The wire end should not be directly inserted into the socket. The temperature of the heat conduction oil temperature control equipment should be replaced in time. The electric heater without the fuse installed in the circuit should not be used. When the temperature control equipment of the heat transfer oil is used, it must be taken care of. When leaving, the plug should be unplugged. In the course of use, if there is a power outage, the plug should be pulled out in time, and should not be forgotten. For the heating wire that has been repaired many times, it is recommended not to use it, and a new heating wire should be replaced. Inflammable and explosive materials are strictly prohibited from drying with heat-conducting oil temperature control equipment. The electric oven should have a temperature-controlled device that prevents the temperature from being too high and prevents the baking time from being too long.
Users and friends, when using heat transfer oil temperature control equipment, can not place flammable materials near the heat transfer oil temperature control equipment, it is recommended to maintain a certain safe distance. (This article is from the source network, if there is any infringement, please contact Lneya to delete, thank you.)
Related recommendations
-
Ultra-high temperature material cold and hot impact box refrigeration oil
1167The ultra-high temperature material impact test chamber test device has too much frozen oil in the evaporator, which can also cause insufficient cooling and cause slow cooling. The oil stored in the evaporator of the ultra-high temperature materia...
View details -
Chiller manufacturers analyze the classification of chillers
909Many industrial productions cannot obtain high-efficiency industrial production without the low-temperature production environment provided by industrial chillers. Therefore, industrial chiller equipment is a very important professional refrigerat...
View details -
Vocs condensing separation equipment expansion valve maintenance instructions
907Once the expansion valve of the vocs condensing and separating device fails, if the solution is not solved in time, the entire vocs condensing and separating device may be unavailable. Therefore, the failure of the expansion valve of the vocs cond...
View details -
Characteristics and Advantages of Air Cooled Chillers
11021. Configuration of air-cooled chillerAir cooled chillers can be divided into air-cooled vortex chillers and air-cooled screw chillers according to the type of compressor. The air-cooled vortex chiller is mainly composed of vortex compressor, evap...
View details