Characteristics and Advantages of Air Cooled Chillers
1. Configuration of air-cooled chiller
Air cooled chillers can be divided into air-cooled vortex chillers and air-cooled screw chillers according to the type of compressor. The air-cooled vortex chiller is mainly composed of vortex compressor, evaporator, condenser, refrigeration element, circulating water pump, stainless steel water tank and original imported fan electric control system. The air-cooled screw chiller is composed of screw compressor, evaporator, condenser, refrigeration components, imported fan and electric control system. All the above parts are guaranteed to be 100% new and original. Welcome new and old customers to our factory for on-site inspection.
2. Protective device of air-cooled chiller
Long service time or improper operation of air-cooled chiller will cause unit failure. In order to ensure the safe and stable operation of chiller, the equipment itself is equipped with multiple safety protection devices, such as reverse phase protection device, compressor overload protection device, high and low pressure protection device, automatic alarm device, low temperature anti icing protection device, etc. Even if the chiller fails, the protection device can be started at the first time to avoid secondary injury to the chiller.
3. Temperature control of air-cooled chiller
Both air-cooled box chillers and air-cooled stacked rod chillers can meet the refrigeration temperature required by various industries, up to 350 ℃ and down to – 150 ℃. Moreover, the temperature adjustment can be set on the control panel of the chiller according to the demand. The specific setting method can be in accordance with the operation manual of the chiller.
4. Energy saving and environmental protection of air-cooled chiller
Chillers belong to mechanical equipment, and the primary problem considered by users is power consumption. One feature of air-cooled chiller is that after reaching the refrigeration temperature required by users, the compressor stops running to save electric energy. When the temperature is higher than the temperature set by the user, the compressor will restart to save power consumption for the user to a certain extent. In addition, for chillers with multiple compressors, each compressor has an independent refrigeration system. Users can decide the number of compressors to be started according to production needs, which is more flexible and convenient to use.
Related recommendations
-
Maintenance of the condenser of high and low temperature circulation device
1190The condenser in the high and low temperature constant temperature circulation device is one of the accessories in the refrigeration process, and its performance is very important. LNEYA reminds the user that regular maintenance is required after ...
View details -
Cooling heating and temperature control equipment for automotive battery test chamber
988The car battery testing chamber high and low temperature integrated machine is a testing equipment that integrates high and low temperature functions, specifically designed to evaluate the performance and durability of car batteries (such as l...
View details -
Design and Test Technology of High Temperature Environmental Chamber Sales
12771. Temperature selection (1) The climatic zones of the region; Whether the product is exposed to the solar radiation environment near the heating device; Surrounding air, solar radiation and ways of heat transfer from heating devices to products;...
View details -
2023 LNEYA Spring Festival holiday notice
1534I have been busy all year, and I am happy to celebrate the new year. The Chinese New Year is coming, and LNEYA is also preparing for the Chinese New Year holiday! Combined with the specific situation of the company, the specific arrangements for ...
View details