SUNDIZ -45℃~+250℃

Cooling capacity 0.9kW~60kW
Heating power 5.5kW~60kW
Medium temp accuracy ±0.1℃
Energy are consumed

Thermal Control Units overview

LNEYA thermal control unit heats and cools to keep the process temperature within range. It handles high heat and adapts cooling and heating to your needs. The SUNDIZ process chiller runs from -45℃ to 250℃, switches between hot and cold, and cools quickly even at high temperatures. It offers ±0.1℃ medium control and ±0.3℃ process control, ideal for pharma, chemical, semiconductor, new energy, and aerospace.

 ModelSUNDIZ4-3
SUNDIZ4-3W
SUNDIZ4-5
SUNDIZ4-5W
SUNDIZ4-10
SUNDIZ4-10W
SUNDIZ4-15WSUNDIZ4-20WSUNDIZ4-30W
Temperature range-45℃~250℃
Heating power5.5kW7.5kW15kW25kW38kW60kW
Cooling  capacity  kW250℃5.5kW7.5kW15kW25 kW38kW60kW
20℃5.5kW7.5kW15 kW25kW38kW60kW
-15℃2.3kW3.6kW7.5 kW11kW15kW33kW
-35℃0.9kW1.5kW3.3 kW5kW6.5kW10kW
Medium temp control accuracy±0.1℃±0.1℃±0.1℃±0.1℃±0.1℃±0.1℃
Process temp control accuracy±0.3℃±0.3℃±0.3℃±0.3℃±0.3℃±0.3℃
Pump flow rate  pressure max50L/min50L/min100L/min150L/min250L/min400L/min
2bar2bar2bar2.5bar2.5bar2.5bar

Thermal Control Units Advantages

VFD energy-saving
SUNDIZ -45℃~250℃ chiller heater unit uses VFD, which can automatically control the output flow and pressure according to the actual cooling and heating needs, reduce power consumption, and save more than 20% energy compared to fixed frequency bandwidth.

Fully enclosed
The SUNDIZ-45℃~250℃ thermal control unit adopts a fully enclosed pipeline design. The heat transfer medium in the expansion container does not participate in the circulation. The expansion tank temperature is maintained at a room temperature of 60℃, which effectively reduces the risk of the heat transfer medium absorbing moisture and volatilizing during the operation of the chiller.

Thermal Control Units Applications


anodizing and electroplating

The thermal control unit is often used to control the temperature of the plating solution and the oxidation tank, thereby improving the treatment quality of the metal surface.

casting process

It is used to control the temperature of the molten metal to prevent thermal stress from causing product defects.

chemical reactions

It is used to control the temperature of reactors and distillation equipment to improve the stability and yield of chemical reactions.


 

Thermal Control Units RELATED

You can trust our portable chiller factory

Global service

30,000 +customers.
20+ countries.

Certification patents

CE ,SGS, ISO certification.

After-sales service

24/7 solutions.

Professional team

15+ years experience.

Quality control

Quality test.

faq

With the alarm function, you can remotely view the real-time status of the device and understand its operation. Before a problem occurs, the device will sound an alarm and prompt the cause of the problem.

Our standard products use plate heat exchangers that can exchange heat efficiently. If you have other needs, you can communicate with us for customization.