SUNDI -25℃~200℃ For Two Reactors

SUNDI -25℃~200℃ For Two Reactors

  • SUNDI -25℃~200℃ For Two Reactors
  • Dynamic Temp Control Systems-1.jpg
SUNDI -25℃~200℃ For Two Reactors


  • Product Description
  • System Introduce
  • Technical Parameter
  • Knowledge Center



● Only the heat conduction medium in the expansion container touches the oxygen in the air. (The container temperature is limited to 60℃).
● No volatilization of the heat conducting medium at high temperature.
● No need to change the heat conducting medium. Continuous control of the temperature of the below range can be done without rising the pressure: -80℃~190℃, -70℃~220℃, -88℃~170℃, -55℃~250℃, -30℃~300℃.

Model SUNDI-225W-2T N
SUNDI-225-2T N
SUNDI-235W-2T N
SUNDI-235-2T N
SUNDI-255W-2T N
SUNDI-255-2T N
SUNDI-275W-2T N
SUNDI-275-2T N
SUNDI-2A10W-2T N
SUNDI-2A10-2T N
Temp. range -25℃~+200℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control process temp. control and jacket temp. control model   TWO  GROUPS
Temp. difference Set or control the temperature difference between jacket oil and raw material process  TWO  GROUPS
Communication Portocol MODBUS RTU Protocol,RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback the temp. of three points: the inlet and outlet of equipment,  reactor material temp.(external temp. sensor)*2
Medium temp. acccuracy ±0.5℃
Material temp. accuracy ±1℃
Heating power kW 2.5*2 3.5*2 5.5*2 7.5*2 10*2
Cooling capacity
kW at  ℃
200℃ 2.5*2 3.5*2 5.5*2 7*2 10*2
100℃ 2.5*2 3.5*2 5.5*2 7*2 10*2
20℃ 2.5*2 3.5*2 5.5*2 7*2 10*2
0℃ 1.5*2 2.5*2 3.5*2 5*2 7.5*2
-20℃ 1*2 1.6*2 2.1*2 3*2 4*2
Circulation pump max
L/min bar
20*2 35*2 35*2 50*2 50*2
1.5 2 2 2 2
Compressor Tecumseh closed compressor Emerson copeland vortex flexible
Expansion valve Emerson thermal expansion valve/danfoss thermal expansion valve.
Evaporator DANFOSS/KAORI Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R507C, optional: R448A
Connection size G3/4 G3/4 G3/4 G3/4 G1
Water-cooled type W(cooling water@20℃) 1200L/H
1.5bar~4bar
1400L/H
1.5bar~4bar
1700L/H
1.5bar~4bar
2100L/H
1.5bar~4bar
2500L/H
1.5bar~4bar
Dimension(water type)cm 55*95*170 70*100*175 70*100*175 80*120*185 100*150*185
Dimension(air type)cm 55*95*170 55*95*170 70*100*175 70*100*175 80*120*185
Weight kg 240 285 345 385 480
Power 380V 50HZ 220V  7.5kW 11.5kW 17kW 23kW 31kW
Production Workshop Real Map:

Typical application of refrigeration heating temperature control system

Dynamic thermostatic control of cold and heat source of high pressure reaction kettle, dynamic thermostatic control of double layer glass reaction kettle, and dynamic thermostatic control of cold and hot source of double-layer reactor.

Microchannel reactor thermostatic control, small temperature control system, steam - feeding system temperature control, material low temperature aging test.
The thermostatic control of the combined chemical cold source heat source, the cooling heating of the semiconductor equipment and the heating temperature of the vacuum chamber are controlled.

Advantages and functions of temperature control system of refrigeration

Temperature range from 120 to 350, performance superior, unique, high - precision, intelligent temperature control.
High cooling power from 0.5 to 1200kW, highest production stability and repeatable results.
Multi-function alarm system and safety function, use plate heat exchanger, tube type heater to increase heating and cooling rate.
7-inch and 10-inch color TFT touch screen graphics display, use magnetic drive pump, no re-seal leakage problem.
Full airtight system, extended thermal conductivity liquid life, very wide temperature range, no need to change liquid media.
Ultra-high temperature cooling technology can be cooled directly from 300 degrees of high temperature.
The principle and the function has many advantages to using staff: because only expansion of cavity in the body heat conduction medium contact with oxygen in the air (and expansion tank temperature at room temperature to 60 degrees), can achieve lower heat conduction medium absorbed by oxidation and the risk of air moisture.
No heat conduction medium evaporates at high temperature, and it can be achieved -80 ~ 190 degrees, -70 ~ 220 degrees, -88 ~ 170 degrees, -55 ~ 250 degrees, -30 ~ 300 degree continuous temperature control without pressurization.

Adopt full closed pipe design, adopt high efficiency plate heat exchanger, reduce the demand of heat conduction liquid, improve the heat utilization rate of the system, reach the rapid lifting temperature.Thermal conductive medium in a closed system, with a container, expand the heat-conducting medium not participate in circulation in the container, whether high or low temperatures, expansion tank temperature to room temperature to 60 degrees, can reduce the heat conduction medium in running the risk of absorb the moisture and volatile.

Cautions of Using Industrial Process Chiller

1. Installation(check whether the machine is damaged, choose a proper place for easy installation and maintenance)

2. The site of the installation unit must be the floor, the installation pad or the foundation, with the level within 6.4mm, and can bear the operating weight of the unit.

3. The unit should be placed in the machine room with a temperature of 4.4-43.3. There should be enough space around and above the unit to carry out routine maintenance work.

4. One end of the unit should be set aside the space to clean the pipe of the condenser tube, and you can also use the door hole or other suitable openings.

5. Select the water pipe with proper pipe diameter, the cooling system and cold water system of the maximum power operation of the unit, and then connect them correctly.

6. For normal uses, the flow rate of evaporator and condenser is allowed between 1.0-3.6m/s.

7. Under any load conditions, the water flow should be stable.

8. For economic and efficient use of water chillers, we suggest that ask water treatment expert analyze of the evaporator and condenser water supply water quality. Because the bad quality will cause fouling to influence heat transfer, or corrosion precipitation and breed organic matter, influence the performance of the unit, increase the operational and maintenance costs.
Related Products
  • Water Cooled Chiller

    Water Cooled Chiller

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • Single Fluid Heat Transfer System SR

    Single Fluid Heat Transfer System SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Temperature System ZLF

    Reactor Temperature System ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview