Classification and advantages and disadvantages of water-cooled chillers
Industrial chillers are divided into air-cooled industrial chillers and water-cooled industrial chillers. Today we will discuss the classification, advantages and disadvantages of water-cooled chillers.
Advantages of water-cooled chillers:
1. Intelligent control data changes in one second to understand the color touch screen to display the set temperature and measured temperature, 7-inch touch screen operation, sensitive touch, simple and quick operation, dynamic display of unit operation.
2. Dynamic monitoring makes dynamics nowhere to escape, dynamic monitoring operation automatically displays the working status of compressors, water pumps, etc., the status of the unit is clear at a glance and is under control.
3. Self-diagnosis is more than intimate, self-diagnosis powerful self-diagnosis function makes it easy for you to diagnose faults.
4. The condensing control is so stable, the condensing temperature control intelligently controls the condensing temperature, high efficiency and energy saving, to ensure the continuous and stable operation of the compressor.
5. Intelligent antifreeze function When the water temperature is low, the unit will automatically enter the antifreeze mode, so there is no need to worry about the unit being damaged by freezing
Water-cooled chiller configuration:
1. Compressor Selected from Emerson and other original imported ming brand compressors. It has the advantages of stable and reliable operation, high efficiency, low failure, good performance, low vibration and low noise, energy saving, convenient maintenance, and long life. According to customer needs and the size of the cold tonnage, a single machine or a combination of multiple machines is used. The compressor can automatically alternate operation according to load changes, automatic energy adjustment, balance the operating hours of each compressor, and greatly extend the service life of the chiller.
2. Condenser It uses copper pipes imported from abroad to be processed into trapezoidal low-rib pipes to enhance heat transfer capacity. The surface of the copper pipe is smooth, which reduces the water pressure and is easy to clean and maintain.
3. Protective device The protection devices of water-cooled chillers include: compressor delay start protector, overload protector, high and low pressure protector, temperature control switch, antifreeze switch, fuse plug, electronic time protection an full valve, compressor overheat protector, compressor Start the protector and abnormal indicator frequently to ensure the normal operation of the unit.
4. Intelligent computer control system The high-intelligence PLC and PC-level computer control system can be used for remote monitoring and control. It has multiple functions such as automatic loading and unloading, timing power on and off, and recording the cause of failure. The operation is simple, and the host is connected to the power supply. The failure rate is low, the an overall factor is high, the installation is simple, the system control can be adjusted in real time, and it is intuitive and reliable.
5. Freezing accessories Refrigeration accessories are all selected from the world's leading brand, the performance is more and more environmentally friendly. For circuit breakers and contactors, select Danfoss brands such as Schneider brand, expansion valve, filter drier, etc.
Disadvantages of water-cooled system: For the open-type cooling water system, as the cooling water absorbs heat and contacts with the air, CO2 escapes into the air, and the dissolved oxygen and turbidity in the water increase, causing the cooling water system to have 4 major problems: corrosion, scaling, The growth of bacteria and sludge. If the water quality is not treated, it will seriously damage the refrigeration equipment, greatly reduce the heat exchange efficiency, and cause a waste of energy. Therefore, it is very important to carry out corrosion inhibition, scale inhibition, and algae-killing treatments for the system water.
Advantages of water-cooled chillers: relatively larger cooling capacity, lower noise, and lower price to sum up
The water-cooled industrial chillers produced by LNEYA can be customized for equipment power, size and temperature range.
February 6, 2021If you need equipment to distill CBD, you need to scrutinize your choices, as the equipment can vary in its features and design. When you use equipment that produces a CBD distillate, you want to seek out a system made by a manufacturer that provides proven and reliable products. You should also work with a business that can train you on the use of the equipment you buy.view
December 5, 2022On November 18, 2022, it was sponsored by the Jiangsu Provincial Association for Science and Technology, the Provincial Taiwan Affairs Office, the Provincial Department of Industry and Information Tec...view
January 13, 2023Recently, the Jiangsu Provincial Productivity Promotion Center officially released the evaluation results of the unicorn enterprises and gazelle enterprises in 2022 in Jiangsu and the high-tech zone, ...view
January 11, 2018Industrial Chiller:Industrial Chiller varies from dynamic temp. Special Chiller:Special Chiller consist of Multi-reactor chiller (TCU).Environmental Chamber:The test object is connected to a testing adapter. Industrial Freezer:Industrial freezer consist oview
July 4, 2018What are the characteristics and functions of ultra low freezer: 1. Ultra low freezer can prevent the precision of machine equipment from being influenced by the change of oil temperature in the proce...view
January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃)
Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
February 28, 2019Temperature control range:-85 ° C ~ 200 ° CPower range:2.5kW~25kWTemperature control accuracy:±0.3°CModelTES-8525WTES-8555WTES-85A10WTES-85A15WTES-85A25WTemp. Range-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃-85℃~200℃Heating P...view