What Maintenance Misunderstanding Should Be Avoided in Cryogenic Refrigeration System
244View details
Search the whole station
When the user chooses the -80 °C refrigerator, it is definitely necessary to have a reliable quality. Wuxi Guanya (LNEYA)-80 °C refrigerator should pay attention to its operation details during operation to avoid equipment failure caused by improper operation.
The following items should be mastered during use. Please check if the -80 °C refrigerator is damaged during installation, and choose the right place for installation and future maintenance. The site where the unit is installed must be the floor, mounting mat or foundation with a level of 6.4 mm and can withstand the operating weight of the unit. – It should be placed in a machine room with a room temperature of 4.4-43.3 °C. There should be enough space around and above the unit for routine maintenance work. A pipe space for cleaning the condenser tube bundle should be left at one end of the device, or a door hole or other suitable hole can be used.
Select the water pipe of the appropriate pipe diameter, the cooling system and the cold water system of the -80 °C refrigerator unit during high power operation, and connect them correctly. For normal applications, the water flow rate through the evaporator and condenser is between 1.0 and 3.6 m/s.
Under any load, the water flow rate should be stable. All chilled water and cooling water pipes should be designed and installed according to the conventional method. The chilled water pump should be located on the inlet pipe of the unit to ensure the positive pressure and flow in the unit. The piping should be provided with a damping tube to ensure proper flexibility and to prevent the evaporator water from being drained when the pump is shut down. The piping should have a solid support independent of the -80 °C refrigeration unit to prevent stress from being applied to the refrigeration unit components. The hangers are set up to facilitate pipe alignment.
-80 °C refrigerator manufacturers will provide corresponding instructions when the equipment is shipped from the factory, users need to read and operate carefully when using.
Generally speaking, the temperature of most chemical reactions will start at room temperature and may need to be gradually increased to promote the reaction. Some reactions need to be carried out within a specific temperature range. For exampl...
View detailsLNEYA tells you that in addition to the refrigeration system, the lubricating oil system is also an important part, with its own oil storage and special oil cooler. Oil level It refers to the level of the lubricant in the oil storage container. Th...