Precautions For Compressor Installation of the Screw Chiller Factory
When the operating conditions of the screw chiller factory restrict the compressor to be installed in a small enclosed space, its ventilation environment should be considered. It is necessary to add ventilation and exhaust equipment to facilitate circulation of air. The capacity of the ventilation and exhaust equipment must be greater than the exhaust volume of the compressor cooling fan, and the exhaust inlet position should be suitable for the hot exhaust outlet position of the compressor. Precautions for compressor installation of the screw chiller factory:
1. The compressor shall adopt a unit with large bearing capacity, and its operating speed and acceleration shall be limited within the permitted range.
2. Try to install the compressor of the screw chiller factory in a cool, clean and well-ventilated place to ensure that the air around the compressor is clean and the moisture content is minimized.
3. The air sucked by the compressor is not allowed to contain combustible gas and corrosive gas, so as not to cause internal explosion or internal embroidery.
4. Air-cooled machines should preferably have exhaust fans or air ducts to direct hot air out of the room to prevent hot air from circulating to the air inlet.
Commissioning of the new screw chiller factory shall be carried out by commissioning technicians designated or approved by the manufacturer. The compressor cannot work under the exhaust pressure higher than that specified on the nameplate, otherwise the motor will be overloaded and burnt out.
When the screw chiller factory is running, strictly check the running direction of the compressor. When reverse rotation is found, stop the machine immediately, cut off the power supply, switch any two of the three-phase lines, and restart the machine. Otherwise, the compressor of the screw chiller factory will be damaged (attention must be paid to each factory power supply overhaul!).
Related recommendations
-
New energy vehicle testing comprehensive test box filled with heat transfer oil
1263In order to ensure the correct operation of the machine, the new energy vehicle inspection integrated test box must ensure that no air bubbles remain in the system, ensure that the heat transfer medium outlet is connected to the lower interface of...
View details -
The reason for the poor cooling effect of the air-cooled chiller of the semiconductor heat sink ther
1058Semiconductor heat sink constanttemperature table Air-cooled chiller is one of the equipment for temperaturecontrol in the semiconductor industry. If the cooling effect is not good, itwill affect the use.The occurrence of this situation is rela...
View details -
What is the reason why the industrial chiller system cannot be cooled
1234Let the LNEYA technical engineer explainthe reason for everyone: The first one: The chiller system fails tolower the temperature during the first use, or there is a problem with theinstallation of the industrial water chiller, cooling tower, ...
View details -
What are the applications of Industrial temperature control machine chillers?
1286Industrial temperature control machine chillers are divided into oil-cooled and water-cooled according to the temperature and medium. The medium used is different for different temperatures, water can be selected for normal temperature, heat tra...
View details