Description of the characteristics of the LNEYA walk-in test chamber
LNEYA walk-in test chamber Characteristics:
Wide temperature control range can meet the user’s various needs.
Unique balanced temperature control method, a stable and balanced heating capacity can be used for high precision and high stable temperature control.
The temperature displayed by touch screen, easy to read, precise and convenient.
The temperature error can be adjusted to meet your more accurate test conditions.
Automatically selecting and running the cooling circuit with the setting of temperature, with simple operation.
The door is equipped with a large observation window, which can observe the test status of the sample.
With high temperature starting function, the chamber can be turned on when the temperature in rises to 100 degrees. It is convenient for continuous round-trip test between high temperature and low temperature.
With self-diagnosis function, overload protection , high pressure switch, overload relay, thermal protection device, etc.
With multi-wing fan used to circulate and avoid any dead Angle, so that the temperature can be distributed evenly in the test area.
The air circuit is designed with the wind return wind, the wind pressure and wind speed are in accordance with the test standard, and can make the opening instant temperature regain fast.
Heating, cooling, and completely independent system can improve efficiency, reduce test cost, increase life span and reduce failure rate.
The water tank is placed on the side of the unit with water shortage and automatic protection.
The humidifying system is separated from the control circuit board, which can avoid the failure of water leakage in the humidified pipeline to improve the safety.
The system of waterway system is opened by door to facilitate maintenance and repair.
In the refrigeration system, the condensation adopts air – cooling mode or water – cooling mode.
LNEYA’s walk-in test chamber has 15 volumes that can be customized.

Related recommendations
-
Working Principle and Process of Chiller Temperature Control and Pressure Controller
565Air cooled chiller temperature controller is a two - position regulator, also known as chiller temperature control relay.According to the change of adjusted temperature,the chiller temperature control makes the contact on or off, thus controlling ...
View details -
Closed Refrigeration Heating Circulator Daily Maintenance Manual
475The closed refrigeration and heating circulators of different manufacturers have a certain life span. Reasonable and correct operation and maintenance of the closed refrigeration heating circulator can effectively extend the service life. The user...
View details -
LNEYA cooling and heating thermostat bath instructions
502Circulating thermostatic water bath is water circulation and cooling function based on the increase in the water bath, can improve the precision of temperature control and temperature stability, can be widely used for drying, distillation, concent...
View details -
Heat sink temperature application note
470As we all know, the semiconductor industry has certain characteristics, small size, high reliability, wide working range, and has a wide range of applications in the civilian, industrial and other fields of semiconductors, but with the increasing ...
View details