The principle and difficulty of temperature control of heating and refrigeration cycle equipment
Heating and refrigeration cycle equipment is equipment for fluid refrigeration, heating and temperature control for reactors, integrated reactors, reaction tanks, etc. At present, there are more manufacturers on the market.
When the reactor or reactor is cooling, heating, and temperature control, the supporting heating and refrigeration cycle equipment controls the temperature to reach the expected temperature control range. This entire process will cause a certain chemical reaction and generate heat. This reaction process is easily affected by the outside world. Affected. Therefore, the placement environment of heating and refrigeration cycle equipment is more important, and it is recommended to choose a ventilated and cool and reliable room for placement.
When the reactor supporting the heating and refrigeration cycle equipment is undergoing polymerization reaction:
There will be a series of exothermic and endothermic reactions. During the chemical reaction, it is recommended that the surrounding operators do not get too close to avoid certain troubles. In the process of the reaction, if the heat is not removed in time, the pressure of the reaction will be affected, and if the pressure is too high, the entire reaction will be at a certain risk.
The heating and refrigeration cycle equipment can be equipped with reactors of different sizes for cooling, heating and temperature control:
Because different sizes of reactors have different heat capacities, their ability to absorb or release heat is also different. Therefore, the selection of heating and refrigeration cycle equipment needs to provide accurate reactor size, temperature requirements, materials and other working conditions for heating. Refrigeration cycle device manufacturers make selections to avoid large or small selections that cause the equipment to fail to meet the expected temperature requirements.
Summarize
The heating and refrigeration cycle equipment can control one or more reactors at the same time. It is a large system device with integrated temperature control, which can be produced according to the requirements of working conditions.
Related recommendations
-
How to deal with the installation of the hot and cold integrated control machine?
580Since the thermocouple's thermal inertia causes the meter's indicated value to lag behind the measured temperature, this effect is particularly pronounced when performing rapid measurements. Therefore, thermocouples with thinner thermal electrodes...
View details -
The importance of constant temperature equipment in oil bath heating systems
431The constant temperature equipment of the oil bath heating system is used for dynamic temperature control of fluid cooling and heating with heat conducting medium, which is applied to high-precision industries such as pharmaceuticals, chemicals a...
View details -
Precautions for non-use of reactor water-cooled chiller shutdown
421When the reactor water-cooled chiller hascomplete accessories, in actual use, it is necessary to provide it with regularrest time. In order to maintain stable performance of the chiller duringlong-term operation, users need to master the method...
View details -
Cooling simulation system for battery pack extreme performance test
529With the development of technology, pure electric vehicles are becoming more and more common, but pure electric vehicles are difficult to get a better solution in terms of cruising range, charging speed, and pollution after battery waste. This mak...
View details