How to deal with organic waste gas treatment refrigerant leakage?
In the process of organic waste gas treatment, if it is found that the refrigerant leaks, it is recommended to treat it in time. LNEYA organic waste gas treatment professional manufacturer then analyzes the knowledge of organic waste gas treatment refrigerant leakage.
Organic waste gas treatment VOCS gas single material or multi-material condensation recovery, the main treatment gases are: hydrocarbons such as gasoline, crude oil, fuel oil, kerosene, diesel, heavy oil, mixed hydrocarbons; aromatics: benzene, toluene, xylene, Styrene, naphtha, etc.; alcohols, ethers, ketones, esters, etc., in the event of a situation, we must now fill the leak or treatment of the refrigerant leakage, then replace the desiccant, re-vacuum treatment, Fill the appropriate refrigerant. When you find that the leaking refrigerant is partially immersed in water, stop the chiller and quickly remove the water from the tank to prevent the compressor from drawing water into the system for more serious damage.

So, what should be done if the organic waste gas treatment refrigerant is found to be insufficient? Organic waste gas treatment failure phenomenon: the whole vehicle refrigeration effect is poor, the air outlet air is only cool, and the manifold pressure gauge check finds that the high pressure is cut and the low pressure side pressure is low (when the compressor speed is 2000/mim, the ambient temperature is about 35C). The low pressure gauge index is lower than 1kg/CM square, the high pressure gauge index is lower than 10kg/CM square, and the bubble flow is visible from the sight glass.
This may be due to a refrigerant leak point in the refrigeration system, resulting in insufficient refrigerant. Treatment method Use an electronic leak detector to detect the leak point and carry out the replacement or replacement of parts. If the parts are not replaced, only the appropriate amount of refrigerant can be replenished; if the parts are replaced, the appropriate amount of refrigerating oil should be added as required, and the refrigerant should be added after the system is vacuumed.
The above is the relevant treatment of organic waste gas treatment refrigerant leakage. If the Wuxi LNEYA organic waste gas treatment equipment fails, it is recommended to solve it in time!
Related recommendations
-
Pharmaceutical chemical industry application – Heating Reactor Temperature Control
1109The pharmaceutical chemical industry involves many chemical reactions. The traditional heating reactor temperature control work efficiency is relatively low, the production cost is relatively high, and the device is relatively cumbersome. To this ...
View details -
LNEYA Low temperature thermostatic bath instructions
1274Low temperature thermostat is widely used in petroleum, chemical industry, electronic instruments, physical, chemical and biological engineering, medicine and health, life sciences, food industry, physical testing and chemical analysis and researc...
View details -
Semiconductor laser automatic temperature control equipment accessories fault solution
1127Semiconductor laser automatic temperature control compressor frosting, may be circulating water circulation or valve is not open, check the water valve, all pipelines, to ensure smooth, install short-circuit pipeline. It may be that the circulatin...
View details -
What is the refrigeration principle of the glycol chiller system
1218Glycol Chiller System , as we can tell fromits name, it is to use Glycol as the refrigeration agent for the chiller. In the all air environment, because of thelow temperature in the outdoors, it is impossible to use a cooling tower tosupply t...
View details