What causes sediment in the use of the chiller cooler?
A chiller is a water-cooled unit that uses water circulation to provide a constant temperature, constant flow and constant pressure cooling water. The LNEYA cold water system has its own working principle, that is, a certain amount of water is injected into the water tank of the machine, the cooling water is cooled by the refrigeration system, and then the cooling water is operated by the compressor. The cooling water is sent to the equipment to be cooled, the heat is taken away, then the temperature rises, and then flows back to the water tank to achieve a cooling effect. However, when using a chiller for a long time, there will usually be some dirt deposits in the chiller pipe or water tank. What is the reason below.
1.Chemical processor
If a zinc salt or a phosphate inhibitor is added to the water circulation system, zinc or phosphate scale is formed. Therefore, we must always carry out maintenance work on the chiller, not only to ensure the cooling capacity, but also to extend the service life of the chiller.
2. Process media leakage
The water cooler leaks, especially if it leaks oil or some organic matter causes deposits to form.
3. Air
Sediments, dust, microorganisms and their spores enter the circulatory system with the air, and sometimes insects are carried into the system, causing the heat exchanger to clog. When the environment surrounding the cooling tower is contaminated, corrosive gases such as hydrogen sulfide, chlorine dioxide and ammonia will react in the unit and indirectly cause deposition.
The LNEYA chiller cooler is a fully enclosed system that does not expose the media to outside air during use.
It can be seen from the above that in the use, the chiller needs to be maintained at all times, which not only ensures the cooling capacity, but also prolongs the service life of the chiller and the saving of circulating water.
If you need any information, you can contact LNEYA to inquire about the use of chiller coolers and other cooling system equipment at sales@lneya.com/LNEYA.COM.
Related recommendations
-
What to do When the High Pressure Alarm of the Chiller?
2047People must pay attention to the maintenance of large-scale temperature control equipment such as industrial water chiller. Sometimes it is normal to encounter high-pressure alarm. We must first find out the causes of high-pressure of the industri...
View details -
Misunderstanding about the operation of the factory boiler
1450The boiler is a very common equipment in the factory. LNEYA Xiaobian tells everyone that many people have misunderstandings about it. Misunderstanding 1 The higher the steam pressure, the better. The choice of boiler steam pressure depends mainly ...
View details -
What reactions are microchannel reactors suitable for?
1683In recent years, micro-chemical technology has developed rapidly, and micro-channel reactors have attracted more and more attention. Microchannel reactors are manufactured with the help of special micromachining technology. They have the advantag...
View details -
How to solve the problem of refrigeration pump circulator pump failure?
1709Cooling heating devices are required in many chemical pharmaceutical and laboratory applications. Then how to solve the failure of the refrigeration heating device is also concerned about how to solve it? 1. Circulating pump failure The circulatin...
View details
LNEYA Industrial Chillers Manufacturer Supplier