LC-WS -25℃~5℃
-25 degree single compressor screw chiller- Cooling Power27kW~238kW
- Power Supply3N/380V/50Hz
- Weight850kG~4345kG
Product Description
1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.
2.Due to continuous updating of product technology, the above data is subject to change without prior notice.
3.In addition to the listed product models, our company can customize non-standard units according to customer requirements.
This series of equipment is suitable for various production process cold sources in the fields of chemical industry, medicine, machinery, etc. It can provide -110℃~30°C refrigeration medium, and can be used as ice storage, low-temperature air supply and other process cold sources required by production processes. Our company can specially design the unit according to the requirements of users. The unit adopts advanced semi-enclosed screw compressor, which is low-carbon, energy-saving and environmentally friendly; it has good performance and low noise, and can run without trouble for more than 100,000 hours; the temperature control can be step-by-step energy regulation or stepless energy regulation control. According to the heat load required by the specific production, the outlet water temperature of the refrigerant is used as the control point, and the control center sends instructions to adjust the movement of the energy regulation slide valve to adjust the load of the compressor unit to achieve a real energy-saving effect.
Parameter
Model LC-WS | 100 | 140 | 180 | 200 | 260 | 310 | 340 | 410 | 470 | 510 | 620 | 710 | 750 | 830 | 930 | |
Cooling capacity-15℃ |
KW | 48 | 64 | 83 | 92 | 124 | 151 | 166 | 197 | 234 | 247 | 305 | 354 | 389 | 418 | 467 |
Kcal/hr *10³ |
41 | 55 | 71 | 79 | 107 | 130 | 143 | 169 | 201 | 212 | 263 | 304 | 335 | 360 | 401 | |
Cooling capacity -20℃ |
KW | 39 | 52 | 68 | 75 | 101 | 123 | 135 | 160 | 191 | 202 | 249 | 289 | 317 | 341 | 380 |
Kcal/hr *10³ |
34 | 45 | 59 | 65 | 87 | 106 | 116 | 138 | 164 | 174 | 214 | 249 | 273 | 293 | 327 | |
Power | 3N/380V/50HZ | |||||||||||||||
Cooling input power |
KW | 27 | 35 | 45 | 50 | 66 | 79 | 86 | 104 | 122 | 129 | 158 | 182 | 203 | 216 | 238 |
Compressor | Form | semi-closed double screw compressor | ||||||||||||||
Heat control range |
0~25~37.5~50~62.5~75~87.5~100(12.5% segmentation control) | |||||||||||||||
Chilled water |
Form | Dry, overflow or falling film heat exchanger | ||||||||||||||
Chilled water volume T/H |
18 | 23 | 27 | 33 | 42 | 51 | 60 | 67 | 79 | 87 | 101 | 113 | 128 | 146 | 160 | |
Water pressure drop KPa |
49 | 60 | 73 | |||||||||||||
Connection size |
DN65 | DN80 | DN100 | DN125 | DN150 | |||||||||||
cooling water |
Form | horizontal and tube sheel type | ||||||||||||||
cooling water volume T/H |
25 | 28 | 33 | 41 | 53 | 62 | 72 | 80 | 107 | 118 | 136 | 150 | 171 | 198 | 213 | |
Water pressure drop KPa |
45 | |||||||||||||||
Connection size |
DN65 | DN80 | DN100 | DN125 | DN150 | |||||||||||
Security device |
High and low voltage protection, anti-icing, heat release protection (double), safety valve, overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc. |
|||||||||||||||
Refrigerant | Charge Kg |
23 | 30 | 35 | 44 | 48 | 55 | 58 | 61 | 75 | 85 | 90 | 115 | 133 | 155 | 165 |
Dimension | Length mm |
2500 | 2585 | 2635 | 2635 | 3100 | 3130 | 3130 | 3135 | 3135 | 3135 | 3135 | 3275 | 3300 | 3300 | 3668 |
Width mm |
850 | 900 | 900 | 900 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | |
Height mm |
1300 | 1335 | 1335 | 1428 | 1428 | 1570 | 1680 | 1776 | 1800 | 1800 | 2000 | 2020 | 2070 | 2100 | 2120 | |
Unit weight |
kg | 850 | 850 | 1050 | 1270 | 1430 | 1740 | 1850 | 2480 | 2600 | 2870 | 3200 | 3400 | 3600 | 3850 | 4345 |
Working weight |
kg | 900 | 900 | 1100 | 1420 | 1580 | 1890 | 2050 | 2580 | 2800 | 3120 | 3500 | 3700 | 3900 | 4150 | 4640 |
You may also be interested in these products
Water Chiller LT 5℃~35℃
Cooling Power 1.8kW to 60kW Conventional chillers can only cool at room temperature
Mini Chiller FL-800
Cooling power 0.35kW~0.9kW Power range 0.6kW
LJ -45°C~ -10°C
Cooling capacity @-20℃ 12kW~360kW Power range 12kW~270kW
LN -60°C~ -10°C
Cooling capacity @-55℃ 6kW~180kW Power range 14kW~300kW
loading…