Instructions for the LNEYA 5hp Freezer Condenser
5hp freezer is one of the most demanding equipments in the industrial cold processing industry. Wuxi Guanya (LNEYA) is one of the related manufacturers, reminding users that when choosing a 5hp freezer condenser, we need to pay attention to the use and maintenance. The matter is clearly understood.
With the operation of the 5hp freezer evaporative condenser, part of the water evaporates, minerals and other impurities in the water are left behind to accumulate in the pool of the evaporative condenser. Therefore, the refrigerant must be inspected regularly and cleaned regularly. Good control of water quality and prevention of scaling. The fresh water should be cleaned with fresh water, and it must be filtered when there is impurities in the water. If the supplemental water is too hard, softened water treatment should also be considered. The water treatment plan should be developed in conjunction with an experienced professional water treatment company.
Always check the operation of the evaporative cold water pump and the fan, and do regular maintenance and inspection. Whether the two components operate normally will directly affect the heat transfer effect. The 5hp freezer evaporative condenser should also consider the antifreeze of circulating water during winter operation, especially in northern China.
Systems using a 5 hp freezer evaporative condenser should note that the presence of non-condensable gases in the system will significantly reduce the heat transfer of the evaporator, resulting in higher condensing pressure. Therefore, the air venting operation must be performed frequently, especially the low temperature system in which the chiller suction pressure is a negative pressure. In actual use of the evaporative condenser, the use state of the evaporative condenser and the number of units used should be adjusted according to the changes in the environment and the area of use in different seasons, so that the system can operate economically and achieve energy saving.
When the 5hp freezer system heat load is relatively small, or the temperature is relatively low, the number of evaporative condensers can be reduced. When the ambient temperature is relatively low, the fan operation is stopped, and only the water pump can be turned on, and the refrigerant is condensed by water alone. When the temperature drops below the freezing point, pay attention to the antifreeze problem of the water, and ensure that the water does not freeze.
Maintenance is important for the use of its equipment, so regular maintenance of the various components of the 5hp freezer is necessary.

Related recommendations
-
Noise description of common faults in high and low temperature integrated equipment
1261High-low temperature integrated machine equipment may cause malfunction due to improper operation, then how to deal with noise failure of the equipment, and then analyze the noise too high. The suction of high and low temperature integrated equipm...
View details -
60P ultra-low temperature water chiller consumes too much energy and needs attention
94760p ultra-low temperature water chillers of different manufacturers have different performance configurations and different energy consumption. If you find that the energy consumption is too large, you must check in time to see if there is a probl...
View details -
What is the thermal chuck temp control system used for semiconductor testing?
1125The integration of temperature control systems and heat cartridges is mainly used in the testing process of the semiconductor industry, serving the following key purposes: Wafer Acceptance Test (WAT): After the completion of semicond...
View details -
Installation Requirements For Ethylene Glycol Cryo Chillers
1054After the purchase of ethylene glycol cryo chillers with professional manufacturers Wuxi Guanya, installation requirements will be sent to the hands of users with the equipment. So, what needs to be paid attention to during the installation of eth...
View details