Precautions for chiller cooling system in low temperature operation test
There are certain differences in the use method, function, structure, etc. of different types of chiller cooling systems for low-temperature operation test.

The chiller of the industrial low-temperature operation test requires heat to be generated during operation. The cooling air should be circulated. There should be a certain space around the installation, and the generated heat should be dissipated upwards, so do not install it around equipment that is not heat-resistant. The chiller of the industrial low-temperature operation test cooling system should be installed directly on the horizontal surface. Do not install it upside down, diagonally or vertically.
The chiller cooling system for industrial low-temperature operation test cannot be installed in places where there are various fibers, paper (chips), metal fragments, etc. The water outlet of the chiller cooling system for industrial low-temperature operation test should be connected with the water inlet of your instrument, and the water outlet of the instrument should be connected with the water inlet of the cooling circulating water machine.
Check whether the air filter, heat exchanger coils and fins of the air-cooled low-temperature operation test cooling system chiller are too dusty. Is the air inlet and outlet dredged? Is the fan and fan blade working normally? Is the wind power normal? Is the water system normal?
Check if the chiller water system of the air-cooled low-temperature operation test cooling system is leaking. Is the water inlet and outlet dredged? Is the pump working normally? Listen to the power on and listen to the air-cooled low-temperature operation test cooling system chiller compressor working sound is normal, whether there is abnormal sound, whether the electric fan, water pump is noisy, whether the noise is too loud, etc. The chiller of the air-cooled low-temperature operation test cooling system is in operation, and under normal conditions, the oscillation is slight and the noise is small.
Check the air-cooled low-temperature operation test cooling system chiller refrigeration system for cracks, damage, frost and condensation and other conditions in the pipes. Whether there is friction between the chiller refrigeration pipes of the air-cooled low-temperature operation test cooling system, the pipes and the shell, etc., especially the welding place of the refrigerant pipe, and whether there is the connection of the chiller joint of the air-cooled low-temperature operation test cooling system Leakage, as long as there is a leak, there will be oil stains. You can also use a clean soft cloth or soft paper to scrub the welded joints and joints of the pipeline, and investigate whether there is any oil stains to determine whether there is a leak.
Check whether the electrical system fuse of the air-cooled low-temperature operation test cooling system chiller is blown, whether the insulation of the electrical wire is intact, whether the circuit board is cracked, whether the connection is loose, etc. Especially if the electrical connection is excellent in touch, the wiring screws and connectors are easy to loose and cause poor touch.
Related recommendations
-
About vocs condensation adsorption machine resonance fault description
1156When choosing vocs condensation adsorption machine, LNEYA recommends selecting reliable vocs condensation adsorption machine equipment to avoid some simple faults, but if a similar resonance fault occurs, it needs to be solved in time. For VOCS ga...
View details -
Methods for Chiller Manufacturers to Ensure Product Quality
1029Before producing the industrial chiller, the chiller manufacturer will consider the applicable industry, refrigeration capacity, structure, etc., and consider the actual use environment during design and assembly to optimize some functions. In ord...
View details -
Impact and Solution of Excess Exhaust Temperature of Industrial Chiller Units
1227Industrial water chiller compressor exhaust temperature determines whether the equipment can stably and efficiently run. The common problem of compressor is excess exhaust temperature. Once the situation appears, it is easy to make industrial chil...
View details -
Low temperature refrigeration unit maintenance inspection
1130Low-temperature refrigeration units usually need to do a maintenance. After the maintenance is done, it is not easy to fail, and there will be more markets. If it is not easy to fail, it will not stop working, which is equivalent to saving the com...
View details