100L high and low temperature thermostat installation instructions
The 100L high and low temperature thermostat uses coolant as the transmission medium to transfer the heat generated by other instruments or equipment that need to be cooled, and dissipate the heat to the outside of the equipment through the refrigeration system, so as to ensure that the equipment works within the normal temperature range. Between instruments and equipment, a closed medium circulation is formed by the pressure of the water pump in the device, and the temperature sensor detects the temperature of the medium to implement the control of the refrigerator.
The 100L high and low temperature thermostat is widely used in a variety of experimental equipment such as: rotary evaporator, x-ray diffractometer, lcp emission spectrometer, ICP mass spectrometer, graphite furnace atomic absorption spectrometer, fluorescence analyzer, electron microscope, production test equipment, CNC machine tools , Laser equipment, etc. This model is an integrated device. The condenser-compressor and evaporator-circulating water pump units are all installed in the same cabinet, and this type of unit is generally installed indoors.
The 100L high and low temperature thermostat should be installed in a laboratory with a good environment. The 100L high and low temperature integrated machine should be installed on a well-ventilated, dust-free and cool solid ground or a test bench to avoid droplets and steam, and avoid possible influx , Where there is stagnation, flammable gas leakage, and near equipment that generates high frequency.
Summarize
The 100L high and low temperature thermostat should avoid places where acidic solutions are frequently used, and places where special sprayers are frequently used. From the consideration of convenience and safety during maintenance and installation, the space between the indoor unit and obstacles should be ensured as much as possible.
Related recommendations
-
Reactor temperature control unit TCU with PID control loop
1194LNEYA reaction kettle temperature control unit tcu adopts PID control loop, which has certain applications in many fields. The reaction kettle temperature control unit tcu of PID control loop adopts fully closed cycle refrigeration system, with fa...
View details -
Compressor key protection of reactor temperature control system
1331In the operation of the reactor temperature control system, the compressor is the core part, and its performance is more important. Therefore, it is necessary to protect the compressor. Under normal working conditions, the compressor of the temper...
View details -
Trouble shooting method for refrigeration device of air-cooled cold water mechanism chemical reactio
1181If air enters into the air-cooled coldwater mechanism refrigeration unit system of the chemical reaction kettle, theimpact will be many. Enter the air circulation system first, the pressure willrise, the heat dissipation effect of the condenser...
View details -
Common Faults and Cause Analysis of Air Cooled Chiller
1249During the use of air-cooled chiller equipment, it is inevitable to encounter some common faults. Users need to understand the possible causes of faults and make corresponding solutions in time, so as to make the production and operation more stab...
View details