Cause Analysis of Poor Cooling Effect of Water Cooled Chiller
Water cooled chillers have been more and more widely used in all walks of life around us. Its main function is to provide industrial chilled water for equipment or products. The water temperature range can be adjusted according to users’ needs, and its accuracy can be accurately controlled at ±1℃. However, in the process of using the chiller, some users encounter the situation that the temperature cannot drop. Let’s analyze it together.

The poor cooling effect of water cooled chillers is mainly due to the following factors:
1. As far as our chillers are concerned, all machines are subject to 100% performance test before leaving the factory to ensure the normal operation of the machines. If the temperature cannot drop during initial use, it may be that the model of water cooled chiller does not match.
2. Another reason why the temperature cannot drop when the water-cooled chiller is used for the first time is that there is a small problem in the installation between the water-cooled chiller and the cooling tower, circulating water pump and pipeline, which needs to be checked carefully according to the installation diagram.
3. If this happens to a water-cooled chiller that has been used for half a year or more, it may be the following problems.
a. The heat exchanger of the chiller is too dirty. It is recommended to clean the heat exchanger and clean it regularly during subsequent use.
b. Freon leakage in the refrigeration system of the chiller. It is recommended to find out the leakage point, repair welding, add refrigerant, etc.
c. It is possible that the ambient temperature of the chiller is relatively bad. Too high or too low ambient temperature will cause the chiller to fail to meet the requirements. In this case, the requirements can only be met by selecting a larger industrial chiller.
4. It may be that the water source used has impurities. After long-term accumulation, impurities will adhere to the pipes between various equipment, resulting in small water flow. Therefore, the pipelines between various equipment shall be cleaned.
In the process of using the equipment, it is necessary to find professional maintenance personnel for maintenance. For users with poor water source, the following professional treatment shall be carried out for the water quality. Special maintenance shall be carried out for the water-cooled chiller at regular intervals, which can effectively prolong the service life of the machine.
Related recommendations
-
Vocs equipment industry heat exchanger type description
987Every accessory in the vocs device has its function, so every accessory in the vocs device can't be less. So what is the heat exchanger in the Wuxi LNEYA vocs device? What are the main types? Tank heat exchanger: Compared with the traditional heat...
View details -
What are the system components of various distillation devices?
8071. A complete set of short-path distillation equipment: including short-path evaporator, heating system, feeding system, cooling system, vacuum system, material collection unit, etc.; 2. A complete set of thin film distillation equipment: includin...
View details -
Precautions for Leakage Inspection of Glycol Chiller
1556The main points about checking leakage of glycol chillerDuring the operation of the glycol chiller, it is critical that the refrigeration system does not leak. In order to avoid the leakage of refrigerant and other gases from the glycol chiller, ...
View details -
How to clean air control system?
1310In order to respond to the requirements of the two types of society in the country, environmental protection and conservation have become increasingly important. Therefore, in order to extend the life of the product, it is still necessary to have ...
View details