Search the whole station

water cooled screw chillers

  • Efficiency

The efficiency of the screw chiller refrigeration determines the efficiency of the process. LG-80℃~30℃ is a water cooled chiller that can operate normally at very high ambient temperatures.

  • Quick return

As a cost-effective screw chiller plant, LG-80℃~30℃ provides lower operating costs, and you can recover your costs in as fast as two years – guaranteed by our 15+ years of design, production, sales, and service experience.

  • Design optimization

People often worry about whether the screw chiller is suitable for placement in their site, and LNEYA solves this problem. We achieve greater flexibility, smaller footprint, and better performance through professional design, and use customized solutions to unlock the limitations of the site.

outdoor chillers

Heating power 3.5kW~15kW

temperature accuracy ±0.3℃

large water chillers

Heating power 2.5kW~10kW

temperature accuracy ±0.3℃

screw water chillers

Circulation Pump MAX 5m³/h~28m³/h 2bar

temperature accuracy ±0.5℃

screw chiller plant

Circulation Pump MAX 2.4m³/h~12.1m³/h 2bar

temperature accuracy ±0.5℃

water cooled screw chillers

Circulation Pump MAX 2.3m³/h~12m³/h 2bar

temperature accuracy ±0.5℃

industrial water coolers

Circulation Pump MAX 2.3m³/h~12m³/h 2bar

temperature accuracy ±0.5℃

Model LG8-75W LG8-100W LG8-140W LG8-180W LG8-230W LG8-280W
Temperature range  -80℃~-30℃
Cooling capacity
-75℃
kW 36 48 67 88 112 131
Kcal/hr*10³ 30.9 41.3  54.2  72.2  96.3  112..3
Power 3N/400V/50HZ
Cooling input power at (-75℃) 83 110  156  203  254  308
Compressor Form semi-closed double screw compressor
Heat control range 25%~100%
Chilled water Form Plate, dry, overflow or falling film heat exchanger
Chilled water volumeT/H 22 30  36  55  70  82 
Water pressure drop 40~80
Connection size DN65 DN80 DN100
Cooling water Form Horizontal tubular heat exchanger
Cooling water volumeT/H 18 23  31  43  54  65 
Water pressure drop 40~80
Connection size DN65 DN80 DN100 DN125

WATER COOLED SCREW CHILLER’S APPLICATIONS

It is generally used for machine cooling and spindle cooling in the production process, temperature control of various drugs and preparation processes in the pharmaceutical field, and temperature control of chemical reactions such as chemical or laboratory crystallization and synthesis, as well as new energy vehicle testing and semiconductor .

Global service

Served more than 30,000 customers.
Exported to more than 20 countries.

Certification patents

Has obtained CE certification, SGS certification, ISO certification.

After-sales service

Provide comprehensive technical training.
With 24/7 solutions.

Professional team

Founded in 2010, with 15 years of industry experience.
20% of employees are technicians.

Quality control

Visual inspection.
Performance test.
Electrical safety test.

Contact us now to get chiller details and prices

The trouble-free operation time can reach more than 100,000 hours.

Yes, according to the heat load, adjust the movement of the energy regulating slide valve and adjust the load of the compressor unit to achieve energy saving effect.

*
*
Submitting….
Submitted successfully!
Submission failed! Please try again later
Email error!
Phone error!

Add our account manager via the QR code below