Search the whole station

Large water chiller

    • High Performance and Low Noise

    These compressors not only perform excellently but also operate quietly. Even during long-term operation, they can run for over 100,000 hours without failure.

    • Intelligent Temperature Control

    The unit features segmented or stepless energy regulation. It adjusts flexibly according to the thermal load requirements during production, ensuring optimal cooling efficiency.

    • Energy-Efficient Control

    By using the outlet temperature of the refrigerant as a control point, the unit’s control center adjusts the compressor load by controlling the movement of the energy regulation valve, achieving actual energy savings.

    outdoor chillers

    Heating power 3.5kW~15kW

    temperature accuracy ±0.3℃

    large water chillers

    Heating power 2.5kW~10kW

    temperature accuracy ±0.3℃

    screw water chillers

    Circulation Pump MAX 5m³/h~28m³/h 2bar

    temperature accuracy ±0.5℃

    screw chiller plant

    Circulation Pump MAX 2.4m³/h~12.1m³/h 2bar

    temperature accuracy ±0.5℃

    water cooled screw chillers

    Circulation Pump MAX 2.3m³/h~12m³/h 2bar

    temperature accuracy ±0.5℃

    industrial water coolers

    Circulation Pump MAX 2.3m³/h~12m³/h 2bar

    temperature accuracy ±0.5℃

    Model LG2-75W LG2-100W LG2-140W LG2-180W LG2-230W LG2-280W
    Temperature range  -25℃~5℃
    Cooling capacity
    -20℃
    kW 80 111 158 206 259 318
    Kcal/hr*10³ 68.8  95.5  135.9  177.2  222.7  273.5 
    Power 3N/400V/50HZ
    Cooling input power at (-20℃) 56 74  105  136  166  205
    Compressor Form semi-closed double screw compressor
    Heat control range 25%~100%
    Chilled water Form   Plate, dry, overflow or falling film heat exchanger
    Chilled water volumeT/H 24 32  46  59  75  92 
    Water pressure drop 40~80
    Connection size DN65 DN80 DN100 DN125
    Cooling water Form Horizontal tubular heat exchanger
    Cooling water volumeT/H 26 35 50 65 80 99
    Water pressure drop 40~80
    Connection size DN80 DN100 DN125 DN150

    LARGE WATER CHILLER ‘S APPLICATIONS

    It is generally used for machine cooling and spindle cooling in the production process, temperature control of various drugs and preparation processes in the pharmaceutical field, and temperature control of chemical reactions such as chemical or laboratory crystallization and synthesis, as well as new energy vehicle testing and semiconductor .

    Global service

    Served more than 30,000 customers.
    Exported to more than 20 countries.

    Certification patents

    Has obtained CE certification, SGS certification, ISO certification.

    After-sales service

    Provide comprehensive technical training.
    With 24/7 solutions.

    Professional team

    Founded in 2010, with 15 years of industry experience.
    20% of employees are technicians.

    Quality control

    Visual inspection.
    Performance test.
    Electrical safety test.

    Contact us now to get screw chiller details and prices.

    Temperature Range
    Consider the production temperature requirements first. Different applications (such as air conditioning and low-temperature projects) have different temperature needs.
    Cooling Capacity and Single Unit Cooling Capacity
    The cooling capacity directly affects the energy efficiency and operating economy. When designing a chiller system, multiple units should be arranged to ensure production continues even if one unit is down.
    Energy Consumption
    Consider both electrical and steam consumption, especially for large systems. The goal is to maximize energy efficiency by considering the combined use of electricity, heat, and cooling.
    Environmental Protection
    Focus on the noise level and the impact of the refrigerants on the environment. Avoid using refrigerants that damage the ozone layer or are harmful to the environment, ensuring that the system meets environmental standards.
    If you have any doubts about choosing the right chiller, feel free to contact us. Our 24/7 customer service team is available to provide professional consultation and offer custom-designed solutions.

    The air cooled screw compressor chiller is mainly composed of the screw compressor, expansion valve, condenser, evaporator, and other components.
    Below is the translation of the specific parts and their functions:
    Screw Compressor  
    It is the power source of the air-cooled screw chiller system. Its main function is to extract the vapor from the evaporator in a timely manner, maintain low temperature and low pressure, and increase the pressure and temperature of the refrigerant vapor through compression, creating conditions for the heat transfer of the refrigerant vapor to the external environment.
    Condenser  
    The air-cooled screw chiller uses a finned condenser. The condenser is a heat exchange device that works by transferring the heat of the high-temperature, high-pressure vapor discharged from the compressor to the surrounding cooling medium.
    Expansion Valve  
    Since the high-pressure, normal-temperature refrigerant liquid cannot be directly sent into the low-temperature, low-pressure evaporator, it needs to be depressurized and its temperature reduced. Therefore, the expansion valve is used to obtain low-temperature, low-pressure refrigerant, which is then sent to the evaporator to absorb heat and vaporize.
     Evaporator  
    Similar to the condenser, the evaporator is also a heat exchange device. It evaporates the low-temperature, low-pressure refrigerant liquid into vapor, absorbs heat from the cooled medium, reduces the temperature of the cooled medium, and provides low-temperature chilled water to achieve cooling. The evaporator, like the condenser, must have a sufficiently large area to work effectively.

    *
    *
    Submitting….
    Submitted successfully!
    Submission failed! Please try again later
    Email error!
    Phone error!

    Add our account manager via the QR code below