Search the whole station

LTZ Variable Frequency Series Low Temperature Chillers

LTZ Variable Frequency Series Low Temperature Chillers

APPLICATIONS

LTZ series low-temperature freezers use frequency conversion technology to achieve high-efficiency energy saving of products, temperature control range: -100℃~30℃, temperature control accuracy: ±0.3℃

The variable frequency compressor unit changes the operating speed of the DC compressor at any time according to the user's cooling and heating load requirements through the built-in frequency conversion device, thereby avoiding the compressor and electric heating full load confrontation, maintaining a stable working state of the unit and achieving energy-saving effects.

Product Features

This series of low temperature chillers has 6 temperature ranges to choose from.

 

Model LTZ-6
LTZ-6W
LTZ-10
LTZ-10W
LTZ-15
LTZ-15W
LTZ-20W LTZ-30W LTZ-40W
Temp range 5℃~30
Temp control accuracy ±0.5
Cooling capacity 20 23kW 40kW 58kW 79kW 110kW 155kW
Circulation Pump MAX 5m³/h 5m³/h 11m³/h 14m³/h 19m³/h 28m³/h
2bar 2bar 2bar 2bar 2bar 2bar
Refrigerant R134A/R407C R410A/R134A
Interface size DN25 DN32 DN40 DN50 DN50 DN65

 

Model LTZ2-6
LTZ2-6W
LTZ2-10
LTZ2-10W
LTZ2-15
LTZ2-15W
LTZ2-20W LTZ2-30W LTZ2-40W
Temp range -25℃~30
Temp control accuracy ±0.5
Cooling capacity -5 10.2kW 18kW 26.5kW 28.4kW 58.5kW 64.5kW
-15 7kW 11kW 16.2kW 18.2kW 39.6kW 43.32kW
Circulation Pump MAX 2.5m³/h 4.2m³/h 6m³/h 6.7m³/h 15m³/h 15m³/h
2bar 2bar 2bar 2bar 2bar 2bar

 

Model LTZ4-6
LTZ4-6W
LTZ4-10
LTZ4-10W
LTZ4-15
LTZ4-15W
LTZ4-20W LTZ4-30W LTZ4-40W
Temp range -45℃~20
Temp control accuracy ±0.5
Cooling capacity -20 5.7kW 9.9kW 14.8kW 18.5kW 28.1kW 32.4kW
-35 2.85kW 5.03kW 7.7kW 10.8kW 14.5kW 17.4kW
Circulation Pump MAX 1.5m³/h 2.4m³/h 3.5m³/h 4.5m³/h 6.8m³/h 7.7m³/h
2bar 2bar 2bar 2bar 2bar 2bar

 

Model LTZ6-6
LTZ6-6W
LTZ6-10
LTZ6-10W
LTZ6-15
LTZ6-15W
LTZ6-20W LTZ6-30W LTZ6-40W
Temp range -60℃~-30
Temp control accuracy ±0.5
Cooling capacity -40 6.2kW 9.1kW 12.8kW 17.5kW 28kW 31.7kW
-55 4.9kW 7.2kW 10kW 13.8kW 22.1kW 25.1kW
Circulation Pump MAX 2.4m³/h 3.8m³/h 5.3m³/h 7m³/h 10m³/h 12.1m³/h
2bar 2bar 2bar 2bar 2bar 2bar
Refrigerant R404A/R23
Interface size DN20 DN25 DN32 DN32 DN40 DN40

 

Model LTZ8-6
LTZ8-6W
LTZ8-10
LTZ8-10W
LTZ8-15
LTZ8-15W
LTZ8-20W LTZ8-30W LTZ8-40W
Temp range -80℃~-50
Temp control accuracy ±0.5
Cooling capacity -60 5.8kW 8.6kW 12kW 16.5kW 26.6kW 30kW
-70 3.7kW 5.5kW 7.7kW 10.6kW 17kW 19.2kW
Circulation Pump MAX 2.3m³/h 3.4m³/h 4.6m³/h 6.5m³/h 11m³/h 12m³/h
2bar 2bar 2bar 2bar 2bar 2bar
Refrigerant R404A/R508B/R23
Interface size DN20 DN25 DN25 DN32 DN40 DN40

 

Model LTZ10-4W LTZ10-6W LTZ10-10W LTZ11-6W LTZ11-10W LTZ11-15W
Temp range -100℃~-65℃ -115℃~-80℃
Cooling capacity -80℃ 0.8kW 1.4kW 2.1kW
-90℃ 0.6kW 1.1kW 1.7kW 1.1kW 1.7kW 2.8kW
-100℃ 0.8kW 1.2kW 2kW
Circulation Pump MAX 20L/min 2bar 20L/min 2bar 30L/min 2bar 20L/min 2bar 30L/min 2bar 40L/min 2bar
Refrigerant Mixed refrigerant 1 Mixed refrigerant 2
Interface size G3/4 G3/4 G3/4 G3/4 G3/4 G3/4
Power 6kW max 8.5kW max 14kW  max  8.5kW max 14kW  max 20kW  max

 

 

APPLICATIONS

Temperature control unit of semiconductor FAB process

Semiconductor manufacturing is a process with extremely high environmental requirements, and many process steps are very sensitive to temperature.
Precise temperature control can ensure uniform thickness and accurate composition of deposited films, thereby improving chip performance and yield.

for Semiconductor packaging & testing process

Semiconductor packaging and testing process is a key link in the semiconductor production process, including wafer testing, chip packaging and post-packaging testing. This process requires not only a high degree of accuracy and reliability, but also strict temperature control to ensure product quality and performance.

*
*