LTZ Variable Frequency Series Refrigeration Circulators Chillers
APPLICATIONS
LTZ series low-temperature freezers use frequency conversion technology to achieve high-efficiency energy saving of products, temperature control range: -100℃~30℃, temperature control accuracy: ±0.3℃
The variable frequency compressor unit changes the operating speed of the DC compressor at any time according to the user's cooling and heating load requirements through the built-in frequency conversion device, thereby avoiding the compressor and electric heating full load confrontation, maintaining a stable working state of the unit and achieving energy-saving effects.
Product Features
Product Parameters
Model | LTZ-6 LTZ-6W |
LTZ-10 LTZ-10W |
LTZ-15 LTZ-15W |
LTZ-20W | LTZ-30W | LTZ-40W |
Temp range | 5℃~30℃ | |||||
Temp control | PLC controller, control the water tank outlet temperature screen | |||||
Temp control accuracy | ±0.5℃ | |||||
Temp feedback | PLC controller, control the water tank outlet temperatureh screen Temperature feedback PT100 (inlet temperature, outlet temperature) | |||||
Cooling capacity 20℃ | 23kW | 40kW | 58kW | 79kW | 110kW | 155kW |
Circulation Pump MAX | 5m³/h | 5m³/h | 11m³/h | 14m³/h | 19m³/h | 28m³/h |
2bar | 2bar | 2bar | 2bar | 2bar | 2bar | |
Compressor | Famous brand compressor | |||||
Evaporator | Plate Heat Exchanger | |||||
Operation panel | 7-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format | |||||
Safety protection | Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions. | |||||
Refrigerant | R134A/R407C | R410A/R134A | ||||
Interface size | DN25 | DN32 | DN40 | DN50 | DN50 | DN65 |
Power | 400V 50HZ / 460V 60HZ |
Model | LTZ2-6 LTZ2-6W |
LTZ2-10 LTZ2-10W |
LTZ2-15 LTZ2-15W |
LTZ2-20W | LTZ2-30W | LTZ2-40W | |
Temp range | -25℃~30℃ | ||||||
Temp control | PLC controller, control the water tank outlet temperature screen | ||||||
Temp control accuracy | ±0.5℃ | ||||||
Temp feedback | PLC controller, control the water tank outlet temperatureh screen Temperature feedback PT100 (inlet temperature, outlet temperature) | ||||||
Cooling capacity | -5℃ | 10.2kW | 18kW | 26.5kW | 28.4kW | 58.5kW | 64.5kW |
-15℃ | 7kW | 11kW | 16.2kW | 18.2kW | 39.6kW | 43.32kW | |
Circulation Pump MAX | 2.5m³/h | 4.2m³/h | 6m³/h | 6.7m³/h | 15m³/h | 15m³/h | |
2bar | 2bar | 2bar | 2bar | 2bar | 2bar | ||
Compressor | Famous brand compressor | ||||||
Evaporator | Plate Heat Exchanger | ||||||
Operation panel | 7-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format | ||||||
Safety protection | Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions. | ||||||
Refrigerant | R404A/R507C | ||||||
Interface size | DN20 | DN25 | DN32 | DN32 | DN50 | DN50 | |
Power | 400V 50HZ / 460V 60HZ |
Model | LTZ4-6 LTZ4-6W |
LTZ4-10 LTZ4-10W |
LTZ4-15 LTZ4-15W |
LTZ4-20W | LTZ4-30W | LTZ4-40W | |
Temp range | -45℃~20℃ | ||||||
Temp control | PLC controller, control the water tank outlet temperature screen | ||||||
Temp control accuracy | ±0.5℃ | ||||||
Temp feedback | PLC controller, control the water tank outlet temperatureh screen Temperature feedback PT100 (inlet temperature, outlet temperature) | ||||||
Cooling capacity | -20℃ | 5.7kW | 9.9kW | 14.8kW | 18.5kW | 28.1kW | 32.4kW |
-35℃ | 2.85kW | 5.03kW | 7.7kW | 10.8kW | 14.5kW | 17.4kW | |
Circulation Pump MAX | 1.5m³/h | 2.4m³/h | 3.5m³/h | 4.5m³/h | 6.8m³/h | 7.7m³/h | |
2bar | 2bar | 2bar | 2bar | 2bar | 2bar | ||
Compressor | Famous brand compressor | ||||||
Evaporator | Plate Heat Exchanger | ||||||
Operation panel | 7-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format | ||||||
Safety protection | Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions. | ||||||
Refrigerant | R404A | ||||||
Interface size | DN15 | DN20 | DN25 | DN25 | DN32 | DN40 | |
Power | 400V 50HZ / 460V 60HZ |
Model | LTZ6-6 LTZ6-6W |
LTZ6-10 LTZ6-10W |
LTZ6-15 LTZ6-15W |
LTZ6-20W | LTZ6-30W | LTZ6-40W | |
Temp range | -60℃~-30℃ | ||||||
Temp control | PLC controller, control the water tank outlet temperature screen | ||||||
Temp control accuracy | ±0.5℃ | ||||||
Temp feedback | PLC controller, control the water tank outlet temperatureh screen Temperature feedback PT100 (inlet temperature, outlet temperature) | ||||||
Cooling capacity | -40℃ | 6.2kW | 9.1kW | 12.8kW | 17.5kW | 28kW | 31.7kW |
-55℃ | 4.9kW | 7.2kW | 10kW | 13.8kW | 22.1kW | 25.1kW | |
Circulation Pump MAX | 2.4m³/h | 3.8m³/h | 5.3m³/h | 7m³/h | 10m³/h | 12.1m³/h | |
2bar | 2bar | 2bar | 2bar | 2bar | 2bar | ||
Compressor | Famous brand compressor | ||||||
Evaporator | Plate Heat Exchanger | ||||||
Operation panel | 7-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format | ||||||
Safety protection | Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions. | ||||||
Refrigerant | R404A/R23 | ||||||
Interface size | DN20 | DN25 | DN32 | DN32 | DN40 | DN40 | |
Power | 400V 50HZ / 460V 60HZ |
Model | LTZ8-6 LTZ8-6W |
LTZ8-10 LTZ8-10W |
LTZ8-15 LTZ8-15W |
LTZ8-20W | LTZ8-30W | LTZ8-40W | |
Temp range | -80℃~-50℃ | ||||||
Temp control | PLC controller, control the water tank outlet temperature screen | ||||||
Temp control accuracy | ±0.5℃ | ||||||
Temp feedback | PLC controller, control the water tank outlet temperatureh screen Temperature feedback PT100 (inlet temperature, outlet temperature) | ||||||
Cooling capacity | -60℃ | 5.8kW | 8.6kW | 12kW | 16.5kW | 26.6kW | 30kW |
-70℃ | 3.7kW | 5.5kW | 7.7kW | 10.6kW | 17kW | 19.2kW | |
Circulation Pump MAX | 2.3m³/h | 3.4m³/h | 4.6m³/h | 6.5m³/h | 11m³/h | 12m³/h | |
2bar | 2bar | 2bar | 2bar | 2bar | 2bar | ||
Compressor | Famous brand compressor | ||||||
Evaporator | Plate Heat Exchanger | ||||||
Operation panel | 7-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format | ||||||
Safety protection | Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions. | ||||||
Refrigerant | R404A/R508B/R23 | ||||||
Interface size | DN20 | DN25 | DN25 | DN32 | DN40 | DN40 | |
Power | 400V 50HZ / 460V 60HZ |
Model | LTZ10-4W | LTZ10-6W | LTZ10-10W | LTZ11-6W | LTZ11-10W | LTZ11-15W | |
Temp range | -100℃~-65℃ | -115℃~-80℃ | |||||
Temp control | PLC controller, control the water tank outlet temperature screen | ||||||
Temp feedback | Temperature feedback PT100 | ||||||
Cooling capacity | -80℃ | 0.8kW | 1.4kW | 2.1kW | |||
-90℃ | 0.6kW | 1.1kW | 1.7kW | 1.1kW | 1.7kW | 2.8kW | |
-100℃ | 0.8kW | 1.2kW | 2kW | ||||
Circulation Pump MAX | 20L/min 2bar | 20L/min 2bar | 30L/min 2bar | 20L/min 2bar | 30L/min 2bar | 40L/min 2bar | |
Compressor | Tecumseh, Emerson Copeland, Carrier | ||||||
Evaporator | Plate Heat Exchanger | ||||||
变频器 | ABB | ||||||
Operation panel | 7-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format | ||||||
Safety protection | Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal protection devices and other safety protection functions. | ||||||
Refrigerant | Mixed refrigerant 1 | Mixed refrigerant 2 | |||||
Interface size | G3/4 | G3/4 | G3/4 | G3/4 | G3/4 | G3/4 | |
Power | 6kW max | 8.5kW max | 14kW max | 8.5kW max | 14kW max | 20kW max |
Get in touch with our chiller experts
Can't find a suitable chiller? Or don't know how to choose a chiller? Contact us now to get chiller details and prices
contact us
Submit your request to us and we will contact you within 24 hours
Variable frequency series saves 20% more energy than Fixed frequency series
Minimum order quantity: 1, 1 unit is also wholesale price.

Your quality chiller manufacturer
lneya uses reliable international brand material accessories, Siemens controllers, Taikang compressors, etc. You can expect our chillers to provide precise temperature control and the best results.
Why choose lneya as your temperature control supplier?
Years of experience
Satisfied Customers
m² Production Area
Patented Technologies
Visit LNEYA factory
Recommend Products