ZLTZ High-efficiency Heat Exchange Chiller
APPLICATIONS
ZLTZ series temperature control unit is combined with cold plates and heat sinks to achieve high heat absorption and high uniformity temperature control. The ZLTZ temperature control unit is combined with ESC chucks, vacuum chucks, etc. to achieve a temperature control range of -65℃~200℃. At the same time, one ZLTZ temperature control unit can be used with multiple ESC chucks to control different temperatures.
Product Features
Product Parameters
Suitable for use in microchannel reactors, plate heat exchangers, cold plates, heat sink plates, tubular reactors and other places with small heat exchange area, large cooling capacity and small temperature difference. The ZLTZ temperature control unit is combined with a microchannel reactor to achieve high heat release temperature control. The equipment can automatically recycle the heat transfer medium. Under the same flow rate, the heat transfer efficiency of the heat transfer oil is more than 5 times higher. At the same time, the inlet and outlet temperature difference is small, and the temperature field is highly uniform, which is particularly suitable for applications with violent exothermic reactions.
ZLTZ -10℃~+25℃
Model | ZLTZ-3 ZLTZ-3W |
ZLTZ-6 ZLTZ-6W |
ZLTZ-10 ZLTZ-10W |
ZLTZ-15W | ZLTZ-20W | ZLTZ-30W | ZLTZ-40W | ZLTZ-75W | ZLTZ-100W | ZLTZ-150W | |
Temperature range | -10℃ ~25℃ | ||||||||||
Cooling capacity | at 0℃ | 8.1kW | 16.25kW | 28.5kW | 40.2kW | 44.6kW | 70.6kW | 89.2kW | 166.5kW | 215kW | 314.9kW |
at -10℃ | 5.48kW | 11kW | 19.35kW | 26.6kW | 29.8kW | 48.2kW | 59.6kW | 118kW | 147.7kW | 226.6kW | |
Interface size | Export | φ12 | φ12 | φ28 | φ28 | φ28 | φ28 | φ42 | DN50 | DN50 | DN65 |
Return | φ20 | φ20 | φ35 | φ35 | φ42 | φ54 | φ54 | DN80 | DN80 | DN100 | |
Water cooling | at 25℃ | 2m3/h | 4m3/h | 6.2m3/h | 10m3/h | 12.2m3/h | 19m3/h | 22m3/h | 38m3/h | 54m3/h | 70.5m3/h |
Cooling water interface | G3/4 | G1 | DN32 | DN40 | DN40 | DN50 | DN65 | DN80 | DN100 | DN100 |
ZLTZ -30℃~+25℃
Model | ZLTZ4-3 ZLTZ4-3W |
ZLTZ4-6 ZLTZ4-6W |
ZLTZ4-10 ZLTZ4-10W |
ZLTZ4-15W | ZLTZ4-20W | ZLTZ4-30W | ZLTZ4-40W | ZLTZ4-75W | ZLTZ4-100W | ZLTZ4-150W | |
Temperature range | -40℃ ~20℃ | ||||||||||
Cooling capacity | at -10℃ | 5.2kW | 11.15kW | 18.4kW | 26.3kW | 31.6kW | 48.2kW | 70.2kW | 124.3kW | 160.4kW | 271.9kW |
at -20℃ | 3.47kW | 7.41kW | 12.3kW | 18.35kW | 21.4kW | 31.4kW | 46kW | 100.1kW | 134kW | 207.8W | |
at -30℃ | 2.24kW | 4.81kW | 7.92kW | 11.8kW | 12.67kW | 19.16kW | 28.2kW | 68.3kW | 90.4kW | 142.3kW | |
at -40℃ | 1.36kW | 2.95kW | 4.7kW | 5.83kW | 6.74kW | 10.45kW | 15.41kW | 42.8kW | 55.2kW | 89.3kW | |
Interface size | Export | φ12 | φ12 | φ16 | φ22 | φ22 | φ28 | φ28 | DN50 | DN50 | DN65 |
Return | φ22 | φ22 | φ35 | φ35 | φ35 | φ54 | φ54 | DN80 | DN80 | DN100 | |
Water cooling | at 25℃ | 2m3/h | 4.2m3/h | 5.3m3/h | 6.2m3/h | 9m3/h | 14m3/h | 20m3/h | 31m3/h | 38.5m3/h | 60m3/h |
Cooling water interface | G3/4 | G1 | DN32 | DN32 | DN40 | DN50 | DN65 | DN65 | DN80 | DN100 |
ZLTZ -65℃~-30℃
Model | ZLTZ8-3 ZLTZ8-3W |
ZLTZ8-6 ZLTZ8-6W |
ZLTZ8-10 ZLTZ8-10W |
ZLTZ8-15W | ZLTZ8-20W | ZLTZ8-30W | ZLTZ8-40W | ZLTZ8-75W | ZLTZ8-100W | ZLTZ8-150W | |
Temperature range | -80℃~ -30℃ | ||||||||||
Cooling capacity | at -30℃ | ||||||||||
at -40℃ | 6.9kW | 14.8kW | 24.4kw | 36.7kW | 42kW | 73.2kW | 110kW | 187.5kW | 257.5kW | 365kW | |
at -60℃ | 3.3kW | 7.1kW | 12kW | 17.4kW | 20kW | 35kW | 52.5kW | 89.3kW | 122.5kW | 173.8kW | |
at -75℃ | 1.65kW | 3.55kW | 6kW | 8.7kW | 10kW | 17.5kW | 26.2kW | 44.7kW | 61.3kW | 87kW | |
Interface size | Export | φ12 | φ12 | φ16 | φ22 | φ22 | φ28 | φ28 | DN40 | DN40 | DN65 |
Return | φ22 | φ22 | φ35 | φ35 | φ35 | φ54 | φ54 | DN80 | DN80 | DN100 | |
Water cooling | at 25℃ | 2.7m3/h | 5.3m3/h | 6.68m3/h | 9.3m3/h | 12.5m3/h | 27.6m3/h | 33.8m3/h | 66.8m3/h | 70m3/h | 125m3/h |
Cooling water interface | G3/4 | DN32 | DN32 | DN40 | DN50 | DN65 | DN80 | DN100 | DN100 | DN150 |
contact us
Submit your request to us and we will contact you within 24 hours
Recommend Products