How is the refrigerant installed in the vocs condensing unit?
The vocs condensing equipment is LNEYA’s equipment for condensing adsorption of various vocs gases. Among them, the refrigerant of vocs condensing equipment is also indispensable. So, how should the refrigerant be treated?
For various refrigeration and heating equipment, generally there are many types of refrigerants, mainly freon, unsaturated hydrocarbon refrigerant, saturated hydrocarbon refrigerant, inorganic compound refrigerant, azeotropic mixture refrigeration. These kinds of agents, etc., generally use environmentally friendly R404 or R22 refrigerant, so you can rest assured when using, do not worry about refrigerant pollution.
In general, vocs condensing equipment generally has two methods when installing refrigerant. One is to use the compressor to remove the valve through hole and directly inject the refrigerant liquid into the system. This method is relatively fast and safe, and is more suitable for filling in the system when it is vacuumed and there is no refrigerant. This method uses the pressure difference and height difference between the refrigerant in the cylinder and the system to discharge into the refrigeration system. Once the filling is insufficient, it can be changed to the suction side. Once it is filled on the high pressure side, Be careful not to start the compressor to avoid accidents.
Another method is to fill the suction port of the compressor suction valve. When using this method, pay attention to the compressor of the vocs condensing device. When filling the liquid, remember to start the compressor and not inject the liquid refrigerant. In order to avoid liquid shock in the vocs condensing equipment. This method is suitable for situations where the system is insufficiently filled and needs to be added.
Need to know more to run vocs condensing equipment, LNEYA’s own vocs condensing equipment, welcome everyone to buy.
Related recommendations
-
How to deal with the equipment failure alarm of the recirculation chiller
955What to do if there is a failure and alarmduring the use of the recirculating chiller equipment? In order to ensureproduction, such problems need to be resolved quickly. We must first understand the causes offailures and alarms, and adopt dif...
View details -
Application of gas cooling temperature control system in optical module
1067The gas cooling temperature control system has a wide range of temperatures and can be widely used to meet the requirements of more production and engineering environments. It is applicable to reliability tests such as chip, microelectronic devi...
View details -
Reactor Cooling Heating System for Pharmaceutical Factory
10451.Process requirements: 2.Media compatibility: 3.Temperature range: 4.Cleanliness requirements: 5.Space and maintenance: In summary, t...
View details -
What do you need to consider for a car battery cooling water cycle heat exchanger?
990The car battery cooling water circulation machine has always been one of the most popular equipments. The design of the heat exchanger piping also needs to be designed. What aspects should be considered? There are many types of heat exchange equip...
View details