Search the whole station

About the components of the reactor chiller refrigeration heating circulator

Industry News News 910

The reactor chiller refrigeration and heating circulator is used to control the heater and cooler, adjust the temperature, and maintain the stable temperature of the material. Through the circulating medium, the temperature of the material can be quickly controlled to further improve the efficiency of the product, so that it can be transported to the cooling equipment normally. Refrigerant, and can make the refrigerant form a continuous circulation loop in the system, so as to reduce the temperature and stabilize the working condition of the coolant.


1. A refrigeration cycle can be formed, but in a complete refrigeration system, some auxiliary equipment should also be installed: gas-liquid separator, high pressure gauge, low pressure gauge, high and low pressure pressure control, oil separator, sight glass, filter , solenoid valve, oil pressure difference, etc.

2. It has the characteristics of high quality, reliability and stability, and is widely used in chemical, pharmaceutical, and other fields, and other equipment for circulating cooling.

3. The compressor sucks the low-temperature and low-pressure refrigerant vapor in the refrigeration system back from the evaporator, and compresses it to form a high-temperature and high-pressure gas. The refrigeration compressor is the main refrigeration equipment in the refrigeration system.

4. The condenser is used to cool the high-temperature and high-pressure gaseous refrigerant discharged from the refrigeration compressor and make it release heat, remove the temperature, and condense the gaseous refrigerant into a gas-liquid mixture under a certain pressure and temperature, most of which are liquid. .

5. Expansion valve, also known as throttle valve, is used to decompress, throttle and expand high-pressure refrigerant liquid into low-temperature, low-pressure liquid.

6. The low temperature and low pressure refrigerant throttled by the expansion valve absorbs the internal surrounding heat and evaporates to achieve the purpose of cooling.

7. In order to flexibly improve and adjust the working conditions, so as to make corresponding adjustments when the working conditions change, and to ensure that the system is shut down in time when individual machines, equipment, and pipelines fail to protect the damage of each equipment, so that the Easy to operate and manage.

8. Fully closed circulation system, the heat transfer fluid is not easy to volatilize and oxidize at high temperature, and it is not easy to absorb moisture in the air at low temperature, which can prolong the service life of the heat transfer fluid.

9. High temperature cooling and refrigeration function, which can directly cool down from high temperature (for example, it can directly cool down from 350 degrees).

10. The fully brazed plate heat exchanger is adopted, which occupies a small space and has high heat exchange efficiency. The liquid level display function can monitor the liquid level at any time to avoid liquid shortage.

The above is a description of the components of our SUNDI series refrigeration heating circulator reactor chiller. If you have other needs to know or even detailed parameters, you can contact us at sales@lneya.com

The prev: The next:
Expand more!