Wuxi Guanya Refrigeration Technology co., ltd

Parts Analysis of Low Temperature Chiller

The low temperature chiller is a cooling water equipment which is widely used. So, when using it, you should first understand the principle of the cryogenic water chiller and its accessories, so as to run the cryogenic water chiller more efficiently.

The low temperature chiller is a kind of water-cooled cooling equipment, which can provide certain constant temperature, constant current and constant pressure refrigeration equipment. It uses the water tank in the machine to inject appropriate amount of water, cooling water through the refrigeration system, and then pumps the cooling water into the equipment that needs to be cooled. The chilled water takes the heat away from the temperature rising water and reaches the water tank to achieve a cooling effect.

Generally speaking, the low temperature chiller is a relatively economical equipment. Generally, refrigerant circulating system, electrical control system and water circulating system complement each other. It is composed of condenser, compressor, thermal expansion valve, evaporator, liquid storage, drying filter, refrigerant and so on.

In the use of the low temperature chiller, the condenser can play a role of heat output. Once the high-pressure gas discharged from compressor operation enters the condenser, it can absorb its heat, and can also transfer other heat in the pipeline to the surrounding media.

Compressor is very important in the low temperature chiller, which belongs to the core part. It can convert electrical energy into mechanical energy. Compression refrigerant is closely related to the operation of other parts.

In the low temperature chiller, the thermal expansion valve regulates the flow rate and is also a throttle valve in refrigeration equipment. It can make the liquid refrigerant of high pressure and normal temperature reduce pressure through the throttle of the thermal expansion valve, and turn into low temperature and low pressure steam to enter the evaporator to gasify and absorb heat, so as to achieve the purpose of cooling.

Of course, the evaporator is also a heat exchanger which uses refrigerant evaporation to achieve the absorption of heat by the low temperature chiller. In addition, in a relatively small low temperature chiller, drying filters are also necessary to prevent some other substances from entering the refrigeration system!

So, before you use the low temperature chiller, you should have a good look at it. After all, there are many knowledge points. You can see more about it.
Related News
Related Products
  • Water Cooled Chiller SLJ

    Water Cooled Chiller SLJ

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • High-Low Temperature Test Chamber

    High-Low Temperature Test Chamber

    March 30, 2018Performance characteristics:1. In the refrigeration system, the condensation adopts air cooling mode, which has a wide temperature control range, which can meet the user's various needs.2. With a unique b...view
  • Humidity Test Chamber

    Humidity Test Chamber

    April 8, 2018Performance characteristics: 1. With wide temperature control range, can meet the user's various needs.2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control canview
  • Single Fluid Heat Transfer TCU SR

    Single Fluid Heat Transfer TCU SR

    April 10, 2018Working temperature range from -25℃to 200℃, other temperature range need to set to the widest temperature range(-50℃to 250℃) Centralized control of 2~20 reactors, each reactor's and jacket temperature can be set independently. One system control multipleview
  • Reactor Material TCU ZLF

    Reactor Material TCU ZLF

    April 10, 2018A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansiview
  • Small Gas Condensing System

    Small Gas Condensing System

    April 10, 2018ModelHQ-0540HQ-1040HQ-2540HQ-5040HQ-0575WHQ-1075WHQ-2575WHQ-5075WGas flow5m3/h10m3/h25m3/h50m3/h5m3/h10m3/h25m3/h50m3/hLowest Temp.-40℃-40℃-40℃-40℃-75℃-75℃-75℃-75℃Primary Temp.There is no-20℃...view
products
Contact
Tel: + 86 13912479193
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat