High precision semiconductor incubator maintenance instructions
The high-precision semiconductor incubator is in the state of the evaporator as a gas refrigerant; after the adiabatic shrinkage of the shrinking machine, it becomes a high-temperature and high-pressure state, and the contracted gas refrigerant is condensed in the condenser by equal pressure, and is converted by condensation. The liquid refrigerant is expanded into a low pressure through a throttle valve to become a gas-liquid mixture. The liquid refrigerant at low temperature and low pressure absorbs the heat of the cold material in the evaporator, and changes from the head to the gaseous refrigerant. The gaseous refrigerant enters the shrinking machine through the pipe and starts the new cycle. This is the high-precision semiconductor thermostat reincarnation. Four processes.
The high-precision semiconductor thermostat sealing part is nursed back. Since the assembled high-precision semiconductor thermostat is made up of several pieces of insulation board, there is a necessary gap between the boards. In the construction, such gaps are sealed with sealant, in order to avoid air. And the water comes in, so in the use of some parts of the seal is not repaired in real time.
High-precision semiconductor incubator ground nursed back, usually the surface of the small-assembled high-precision semiconductor incubator uses thermal insulation board. When using high-precision semiconductor incubator, in order to avoid a large amount of ice and water on the ground, if there is ice, it must not be processed. Use hard objects to knock and damage the ground.

High-precision semiconductor incubators are used after assembly or long-term deactivation. The rate of cooling should be appropriate: daily operation at 8-10 °C is appropriate, and should be retained for a period of time at 0 °C.
High-precision semiconductor thermostat library board nursery, pay attention to the use should pay attention to the collision and scratching of the hard object on the library, in view of the possibility of becoming the concave and rust of the library board, it will seriously reduce the surface insulation function of the library.
The maintenance of high-precision semiconductor incubators is inseparable from the careful operation of our operators, so we should be kind to our equipment in daily operations, not too rough.
Related recommendations
-
What should pay attention to after purchasing the -150°C ultra-low temperature refrigerator?
559-150 ° C ultra-low temperature refrigerator is used in the industry, so what should users pay attention to after purchasing equipment from the manufacturer? Next, Wuxi Guanya (LNEYA)-150 °C ultra-low temperature refrigerator manufacturers for ever...
View details -
Low-temperature refrigerator manufacturers’ energy adjustment instructions
451The energy regulation of low-temperature refrigerator manufacturers' equipment during operation is also very important. In order to adapt to the change of energy load, Wuxi Guanya (LNEYA) low-temperature refrigerator manufacturers should pay atten...
View details -
Common Faults of Salt Spray Environmental Chambers
437The enterprise users are often at a loss when dealing with common faults in the salt spray environmental chamber. For this reason, Wuxi LNEYA, a manufacturer of the salt spray environmental chamber, specially reorganized the related common fault t...
View details -
Ultra-low temperature refrigeration circulator condenser maintenance instructions
654Maintenance is an important task for users of ultra-low temperature refrigeration circulators. Wuxi Guanya LNEYA reminds that the maintenance of the condenser is a relatively important task in its maintenance work. So what should be paid attention...
View details