Factors affecting cooling capacity during temperature control of battery test equipment
Battery Test Equipment Refrigeration System The greater the power of the battery test equipment compressor, the higher the cooling capacity. According to the size of the battery test equipment, the compressors of different types are selected. For example, the small battery test equipment is piston type, and the medium type is optional. Scroll type. When the water temperature of the battery test equipment (the evaporation temperature is different, the cooling capacity is different), the higher the cooling capacity, the lower the water temperature, the smaller the cooling capacity. Battery test equipment pump power water circulation amount, directly affects heat transfer speed, evaporator, condenser form, divided into water tank coil test, shell tube type, stainless steel plate type, etc., we need to configure according to certain requirements, thermal material Medium copper tube heat transfer is better.

There are also external factors affecting the cooling capacity of battery test equipment. Most of the battery test equipment is air-cooled. Therefore, the external ambient temperature needs to be within a reasonable range. The condensation temperature should not exceed 45 degrees. Once the cooling capacity is exceeded, it will be significantly weakened. Can not be too low, the battery test equipment air is also very important for convection, the vents can not have a barrier, reference to the standard outlet vents can not have obstacles within 1 meter.
The cooling capacity of the battery test equipment is related to the operation process of the entire battery test equipment. Therefore, the cooling capacity of the battery test equipment must be guaranteed, so that the battery and the motor operate well in the process of cooling and heating.
Related recommendations
-
Temperature control of dynamic temperature control system in process engineering
952In the chemical industry, especially in process engineering, many processes are bound to a temperature, or can be supported by specific temperature control applications, thereby making efficiency higher. An example of the latter is continuous temp...
View details -
Common faults of plate heat exchangers in new energy vehicle inspection
1445The reason for the excessive pressure drop of the new energy vehicle detection is that the running system pipeline is not properly purged, especially in the newly installed system pipeline, many dirt (such as welding slag) enters the interior of t...
View details -
LNEYA semiconductor refrigeration unit common fault description
1434If a high-voltage alarm occurs in the semiconductor refrigeration unit, it is necessary to check whether the external piping is blocked or dirty. Clean and remove in time. If it is an air-cooled semiconductor refrigeration device, it is necessary ...
View details -
What should I do if the 30p Refrigerated chiller compressors are overheated?
1323When users purchase 30p Refrigerated chiller, they understand the internal configuration. The compressor is an important accessory in 30p Refrigerated chiller. If it overheats, 30p Refrigerated chiller will be unavailable, then 30p Refrigerated ch...
View details