Wuxi Guanya Refrigeration Technology co., ltd
Recirculating Chiller LC

Recirculating Chiller LC

  • Recirculating Chiller LC
  • Ultra-Low Temp. Water-Cooled Chiller-1.JPG
  • Ultra-Low Temp. Water-Cooled Chiller-2.JPG
  • Ultra-Low Temp. Water-Cooled Chiller-3.JPG
Recirculating Chiller LC


  • Product Description
  • Knowledge Center

-25℃~-5℃

Technical Parameters:



Model LC-12W LC-20W LC-30W LC-40W LC-60W LC-80W LC-120W LC-180W LC-240W LC-360W
Temperature Range -25°C~ 5°C
Cooling Capacity
At -20°C
12kw 20kw 30kw 40kw 60kw 80kw 120kw 180kw 240kw 360kw
10320Kcal/h 17200Kcal/h 25800Kcal/h 34400Kcal/h 51600Kcal/h 68800Kcal/h 103200Kcal/h 154800Kcal/h 206400Kcal/h 309600Kcal/h
Circulation Pump Info 6.6m³/h 9m³/h 15m³/h 15m³/h 25m³/h 25m³/h 25m³/h 35m³/h 35m³/h 50m³/h
2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max
Inlet&outlet connection size DN-25
PN-10
DN-25
PN-10
DN-32
PN-10
DN-32
PN-10
DN-40
PN-10
DN-40
PN-10
DN-40
PN-10
DN-50
PN-10
DN-50
PN-10
DN-65
PN-10
Cooling Water at 30 degree 8m³/h 10m³/h 16m³/h 20m³/h 25m³/h 30m³/h 38m³/h 55m³/h 70m³/h 100m³/h
Cold Storage tank (optional) 200L 350L 500L 750L 1000L 1200L 1500L 2200L 3000L 4000L
Expansion tank(standard) 100L 175L 250L 350L 500L 600L 750L 1000L 1350L 1800L
Compressor Dorin semi-closed compressor Dorin compressor/HANBELL、Fusheng、Bitzer screw compressor
Operation Panel 7-inch color touch screen display, temperature curve record
Control System Standard: Single-chip micocomputer controller; Stepping control; Set temperature difference of refrigeration on & off
Optional: SIEMENS S7-200PLC&Module
Closed Circulation System The whole system is a full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature
Circulation Pump LNEYA Mangetic Pump/German Brand Mangetic Pump
Evaporator Danfoss/KAORI plate heat exchanger
Condenser Casing type water-cooled condenser / tube-type water-cooled condenser
Intermediate heat exchanger Danfoss/KAORI plate heat exchanger
Refrigeration accessory Oil separators, drying filters, expansion valves, refrigeration solenoid valves, pressure control, mirrors, etc. all use Emerson / Danfoss and other brands
Electric AC contactors, intermediate relays, circuit breakers, thermal relays, etc. are Schneider / ABB brand
Refrigerant R404A/R507C, optional: R448A
Secondary refrigerant Non-corrosive liquid, aqueous ethanol solution, aqueous glycol solution, heat transfer oil, etc.
Safety Protection High pressure protect; water supply cut-off protection; over-current protection; leakage protection; sequential and phase failure protection; High temperature protection; Sensor Failure protection; Liquid low level protection etc. multi-safety protection
Level Indicator Adopt glass liquid level indication
Piping material Expansion tank, cold storage tank and circulation pipeline are all made of SUS304
Case material Channel steel + square tube + cold rolled plate sealing plate        Spray
Dimension cm 100*150*185 100*150*185 205*145*205 205*145*205 205*145*175 245*145*205 300*160*225 350*160*205 400*160*225 500*200*225
Power 10kW max 14kW max 22kW max 31kW max 45kW max 61kW max 86kW max 127kW max 167kW max 247kW max
dB within 75 dB within 80 dB within 90 dB
Weight (kg) 800 950 1100 1350 1500 1800 2400 3100 3600 5000

PRODUCTION WORKSHOP REAL MAP:

After running for a period of time, the normal operation of ultra-low temperature circulating water chiller needs comprehensive maintenance and maintenance. For many enterprises, due to the weak consciousness of daily maintenance, the cryogenic cycle water chiller has been used for a long time without maintenance. If the low-temperature cycle chiller is lack of necessary maintenance, the failure rate of the ultra-low temperature circulating water chiller will be pretty high in the later period.

There will be a large range of incrustation problem after an industrial long-term cryogenic operation of circulating water chiller. If the incrustation cannot be effectively cleaned up, the range of incrustation will continuously extend after a long time of accumulation, which will directly affect the industrial circulation chillers of ultra-low temperature.

If the ultra-low temperature recirculating chillers frequently used in a hostile environment, shorten the cleaning time to three months in order to reduce the probability of all kinds of malfunctions of the industrial ultra-low temperature chiller.

As long as there are some problems such as the increase of energy consumption, the comprehensive cleaning, and maintenance of the industrial ultra-low temperature circulating water chiller can be carried out. Proper cleaning and maintenance can extend the service life of ultra-low temperature cycle chillers, and avoid all kinds of faults to affect the safe operation of industrial ultra-low temperature cycle chillers.

Related Products
  • Water Cooled Chiller SLJ

    Water Cooled Chiller SLJ

    January 11, 2018Temperature ranges from - 5 ~ - 150 ℃, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • High-Low Temperature Test Chamber

    High-Low Temperature Test Chamber

    March 30, 2018Performance characteristics:1. In the refrigeration system, the condensation adopts air cooling mode, which has a wide temperature control range, which can meet the user's various needs.2. With a unique b...view
  • Humidity Test Chamber

    Humidity Test Chamber

    April 8, 2018Performance characteristics: 1. With wide temperature control range, can meet the user's various needs.2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control canview
Leave a Message Email Us

we will contact you within 24 hours.

products
Contact
Tel: + 86 13912479193
E-mail: sales@cnzlj.com
Add: No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province, China
code chat