Basic maintenance of high and low temperature refrigeration circulating pumps
Properly perform the sequence of opening and closing of the high and low temperature refrigeration cycle pump group to ensure normal operation after the host is started. Note that the condenser heats up well, otherwise the high temperature protection device of the high and low temperature refrigeration cycle pump group will stop and even cause malfunction due to the condensing temperature and the corresponding condensing pressure being too high. The cold water in the evaporator should be circulated, otherwise the cold water temperature will be low, the cold water temperature protection device will stop, or the low temperature protection device will stop due to the evaporation temperature and the corresponding evaporation pressure being too low, even leading to the evaporator. Cold water freezes and damages equipment.

Therefore, the boot sequence is: (must be strictly observed) Cooling tower fan on → cooling water pump on → cold water pump on → high and low temperature refrigeration cycle pump group. The shutdown sequence of the high and low temperature refrigeration circulating pump set is: (must be strictly observed) The equipment group stops → the cooling tower fan stops → the cooling water pump stops → the cold water pump stops. When the machine is shut down, the equipment group should be shut down half an hour before leaving work. The cold water pump is shut down after work, which is conducive to saving energy, avoiding downtime and protecting the unit. Before running the high and low temperature refrigeration cycle pump refrigeration cycle, make sure that the heating cycle pipe valves are all closed.
Maintenance of high and low temperature refrigeration circulating pumps is indispensable. At the same time, the operator needs to have certain operational knowledge of the equipment and will not find operational faults.
Related recommendations
-
Vocs equipment industry heat exchanger type description
1058Every accessory in the vocs device has its function, so every accessory in the vocs device can't be less. So what is the heat exchanger in the Wuxi LNEYA vocs device? What are the main types? Tank heat exchanger: Compared with the traditional heat...
View details -
How to check the cooling effect of industrial refrigerators?
1027For the user, how to check the cooling effect of the industrial refrigerator is an important part. LNEYA adopts a single-machine self-cascading refrigeration system. The environmentally friendly refrigerant and refrigeration effect users have a de...
View details -
High and low temperature device related instrument maintenance instructions
1163The liquid medium should be added before the high and low temperature circulation device is used. The liquid medium generally uses more than 95% alcohol, and the liquid medium cannot be lower than the working plate 20mm. The high and low temperatu...
View details -
After Adding A Backwater to the Heater, Hot Water Will Come Out Anytime and Anywhere in Winter
1012The principle is also simple. A water pipe is added at the outlet of the hot water pipe to form a closed circuit. The recirculation pump is connected to the water heater. When the tap is turned on, the circulating pump automatically pumps the col...
View details