Precautions for the use of LNEYA chillers in industrial processes
1. Installation (check the machine for damage, choose the right location for installation and maintenance)
2. The location of the installation unit must be the floor, mounting mat or foundation, the level is within 6.4mm, and can withstand the working weight of the unit.
3. The equipment should be placed in the equipment room at a temperature of 4.4-43.3. There should be enough space around the equipment and above for routine maintenance work.
4. Space should be left at one end of the unit to clean the tubes of the condenser tubes. Door openings or other suitable openings can also be used.
5. Select the water pipe with the proper diameter of the pipe, the cooling system and the cold water system running at the maximum power of the equipment, and then connect them correctly.
6. For normal use, the flow rate of the evaporator and condenser is allowed to be between 1.0 and 3.6 m / s.
7. Under any load conditions, the water flow should be stable.
8. In order to use the chiller cost-effectively, we recommend that water treatment experts analyze the water quality of the evaporator and condenser water supply. Poor quality can cause dirt to affect heat transfer, or corrosion and precipitation and growth of organic matter, affecting unit performance and increasing operating and maintenance costs.

Related recommendations
-
Ways to make ultra-low temperature circulating chillers more energy-efficient
824In modern times, environmental protectionand energy saving is the development theme, so is the industrial chiller. Then,how to improve your industrial chiller to be more energy conservation? First, to prevent and reduce the pipescaling of ult...
View details -
Brand Tips of Ultra Low Temperature Freezer
907When it comes to ultra low temperature freezer, a majority of people will get worried because ultra low temperature means the technology becomes more challenging. Compared with other refrigerant plants, the choices of ultra low temperature freezer...
View details -
The Method That Small Water Cooled Chiller Needs To Follow When Charging Refrigerant
1183In our life, we believe that everyone is very familiar with refrigeration. In the central air conditioning and industrial production process cooling industry, small water cooled chiller is more common. This unit is composed of a compressor in the ...
View details -
What are the effects of the oil separator on the equipment analyzed by the chiller manufacturer
907Oil separators use more accessories in thechiller refrigeration system. So as users, we need to understand where the mainimpact is in order to better use the equipment.In the configuration of the chiller, theposition of the oil separator is aft...
View details