Instructions to Use Industrial Cryogenic Refrigerator
Industrial refrigerators are one of the cold water machines. It is classified according to the cooling mode of the cold water machine itself. It is divided into air cooling type refrigerators and water cooled refrigerators.
Structural features: a standard refrigerator freezer is composed of a compressor, condenser, evaporator, filter drier, expansion throttling valve of the five most series, note the amount of refrigerant inside (refrigerant), the electrical appliances (including controller) according to the requirement of the environment and control the operation of the compressor to achieve the purpose of heat transfer and refrigeration.
With the progress of the society, the industry has also been developed rapidly. Today, we will discuss the use of the laboratory refrigerator (industrial refrigerator).
1. Always check the sealing strip of the outer door.
2. Place it firmly and horizontally on the ground when carrying.
3. Clean the filter once a month (use a vacuum cleaner to suck, rinse it with water, finally dry and reset the filter), and suck the dust on the internal condenser with a vacuum cleaner in every two months.

4. When defrosting, you should cut off the power and open the door. When the ice and cream begin to melt, put in each layer of the refrigerator clean and bibulous cloth.
5. Clean it every month to make sure it is clean.
6. Remove the small amount of the dustin the fridge on the internal and external and accessories with dry cloth. If the fridge is too dirty, use neutral detergent and wash thoroughly with clean water after washing. Do not rinse the inside and upside of the refrigerator with water, otherwise, it will damage the insulation and cause failure.
7. Don’t put the lubricating oil to the compressor and other mechanical parts.
8. Take care when cleaning the fans in the back of the compressor.
9. The maintenance and maintenance of cryogenic refrigerator is particularly important to extend the life and the normal use. If the temperature control is not accurate, it often leads to damage the saved objects which will cause great influence to the experimental results, thus affecting the normal work.
Related recommendations
-
Parts Analysis of Low Temperature Chiller
1205The low temperature chiller is a cooling water equipment which is widely used. So, when using it, you should first understand the principle of the cryogenic water chiller and its accessories, so as to run the cryogenic water chiller more efficient...
View details -
Advantages and disadvantages of water-cooled chillers
1136The water-cooled industrial chillers produced by LNEYA are refrigeration equipment that provides chilled water. Today we will discuss the classification, advantages and disadvantages of water-cooled chillers. Water-cooled chiller configuration: 1....
View details -
How does the cooling and heating circulator equipment control the temperature of the jacket glass re
944The cooling and heating circulator equipment is often equipped with a reaction kettle for temperature control, so how to connect and control the temperature? 1. Circular jacket inlet and outlet interface We mainly use flange interfaces for the in...
View details -
Daily maintenance instructions for heating and cooling circulators
1055After the heating and cooling circulator has been running for a long time, certain maintenance work needs to be carried out, so what should be paid attention to? To ensure the normal operation of the heating and cooling circulator after it is star...
View details