LNEYA semiconductor component test device design
The semiconductor component test device is used for high and low temperature test operation in the semiconductor and component industries. The LNEYA semiconductor component test device utilizes its advantages in the field of refrigeration and heating dynamic temperature control systems to produce semiconductor component test devices, which are compared in the industry. Big.
When the semiconductor component tester system performs low temperature detection, the optical window on the vacuum low temperature chamber is necessary to maintain the indoor vacuum seal. However, the light used for interferometry passes through the window, and the effects of the optical window on system interference detection must be carefully considered. Optical windows are generally made of parallel plates made of stabilized explosion-proof glass, which have strict requirements on the optical properties of the material, the flatness and parallelism of the two surfaces. The parallel plates are in the detected light path. If the detection optical path is a converging beam, the parallel plate necessarily introduces aberrations (ie, spherical aberration), which causes detection errors. It is found by calculation that the optical path difference caused by the optical window can be compensated by the defocus of the interferometer. In actual operation, proper defocus can be selected so that the total measurement error is small and the influence of the optical window can be ignored.
When the inside of the low temperature chamber is evacuated, there is an atmospheric pressure difference between the two sides of the window, which corresponds to a pressure of 280 Newtons on the window area. In principle, such a large force creates stresses inside the window, causing a change in refractive index, introducing additional wave differences. The calculations show that the stress generated by the atmospheric pressure inside the window is large in the outer ring, small in the middle, and zero at the center point. If the detection scheme of the large-aperture parallel beam passing through the window is adopted, the influence of the air pressure will be very serious; if the detection optical path passes through a small area in the center of the window in the form of convergence, the contribution of the air pressure to the optical path difference of the window will be very small.
The semiconductor component test device can measure the temperature of the sample, raise the voltage of the regulator, heat the sample by the radiant heater, increase the temperature of the sample, measure the conductivity and luminous intensity of the sample at high temperature, and draw the temperature rise. The curve of these physical quantities is high.
The semiconductor component test device can be applied to various fields of materials science, and can test various materials, devices, etc. at low temperature for electrical conductivity and luminescence performance, especially the temperature that can be reached above the critical temperature of some high temperature superconducting materials. It can provide some help for this research. The long-span temperature range can be tested at high and low temperatures for the properties of special materials such as the conductivity of semiconductor wafers, the deformation of weapons, aerial photography, and space-capture optics.
The LNEYA semiconductor component tester is developed for semiconductor materials and is suitable for testing and operation in various temperature environments in various semiconductor materials.
(Note: Some of the original content is from related papers. If infringement, please contact us in time to delete, thank you.)
Related recommendations
-
Exhibition Preview | 2019 China International Automotive Testing Quality Monitoring Expo
1803Autumn is cool, the exhibition season is here again!For you to present Wuxi Guanya LNEYA exhibition information: We invite you to attend:2019 China International Automotive Testing and Quality Control ExpoExhibition time: September 24-26Exhibi...
View details -
Explanation of Abnormal Condenser Temperature of Glycol Chiller
1803In the glycol chiller, the condenser temperature is the saturation temperature when the refrigerant in the condenser condenses under the steam pressure. Once the condenser temperature in the glycol chiller is abnormal, we should analyze the specif...
View details -
How to control the temperature of solvent recovery by distillation?
15731. If the product quality is not affected by the presence of air at a higher temperature, it can be recovered at normal pressure first, and when the temperature exceeds the normal pressure boiling point of the desolvent by 10 degrees, when the so...
View details -
LNEYA microfluidic chip test solution
1734The microfluidic chip test is a program for testing the drive control chip. The LNEYA microfluidic chip test device specializes in processing various chip tests, and has certain advantages for the development of the chip environment. In order to i...
View details
LNEYA Industrial Chillers Manufacturer Supplier