Core Maintenance Points of Ten High and Low Temperature Test Chamber Manufacturers
According to many years’ production experience of high and low temperature test chamber in Wuxi Guanya, it is found that many users are not very familiar with the maintenance of high and low temperature test chamber. As one of the top ten manufacturers of high and low temperature test chamber, Wuxi Guanya has sorted out the relevant maintenance points, and everyone pays attention to the analysis.
Enterprise users need to have a comprehensive understanding of the products of ten manufacturers of high and low temperature test chamber before choosing. Because of the lack of correct judgment and sufficient recognition, enterprises can not choose high-quality high and low temperature test chamber. Among them, compressors, controllers, electronic devices, boxes and hardware fittings are very important, so the role of each component is very important and nursing is very important.
Cleaning of waterway and humidifier
If the waterway of the high and low temperature test chamber is not smooth, the scaling of the humidifier will easily lead to the dry burning of the humidifier, which may damage the humidifier. Therefore, the high and low temperature test chamber must be cleaned regularly for the waterway and the humidifier.
Selection of Test Environment
Generally speaking, the box of high and low temperature test chamber is relatively high. Ten manufacturers of high and low temperature test chamber suggest that it should be placed in a benign temperature environment when using. For laboratories that do not meet this requirement, it is necessary to equip with appropriate air conditioners.
Clean evaporator regularly
Many small particles such as dust will condense on the evaporator under the forced air circulation of the test sample in the high and low temperature test chamber. It needs to be cleaned regularly in the high and low temperature test chamber, otherwise it will seriously affect the normal use of the equipment.
Clean condenser regularly
The common high and low temperature test chamber usually uses air-cooled cooling compressor, so it is necessary to repair the condenser fan regularly and remove the dirt and dust from the condenser so as to obtain good ventilation and heat transfer performance.
These high and low temperature test chamber ten manufacturers collated the relevant maintenance knowledge, you can pay attention to check the early formulation of maintenance plan.
Related recommendations
-
LNEYA temperature control system AH series commentary
1173Refrigeration heating temperature control system AH series, suitable for high heat release, suitable for SUS reactor, temperature difference > 150 ° C, can quickly cool high temperature reaction, polymerization reaction and rapid heating and co...
View details -
Heavy Industry Workpiece Cold Assembly Freezer
845In the heavy industry, cold assembly freezers (also called industrial freezers or cryogenic freezers) are used to cool and store large workpieces or materials to meet specific process requirements. This equipment is often used in metal...
View details -
Energy storage system requirements for temperature-controlled liquid-cooled unit
1502Energy storage system: It needs to meet the discharge demand for a long time. It is suitable for energy storage on the side of new energy generation, arbitrage of peak-valley price difference on the user side, etc. The future trend is that...
View details -
Precautions for Leakage Inspection of Glycol Chiller
1646The main points about checking leakage of glycol chillerDuring the operation of the glycol chiller, it is critical that the refrigeration system does not leak. In order to avoid the leakage of refrigerant and other gases from the glycol chiller, ...
View details