TCU temperature control model selection and technical parameter description
TCU temperature control is also a two-cycle unit single-fluid temperature control system. When selecting the model, it is very important for the whole temperature control reaction. Only the appropriate reaction system is used to exotherm and absorb the whole reaction process. The heat responds to the entire control, so the choice of model is very important.
TCU temperature control model: SR-10
Model SR-10 with operating temperature range of -120~200°C, suitable reaction vessel is 50L-250L, circulating pump flow pressure is controlled at 3m3/h1.5bar, circulating pump can not be adjusted, auxiliary heating power is 10KW, pre- The interface of the heat exchange module is DN25, and electric power, steam, hot oil, hot water, cooling water, chilled water and ultra-low temperature medium can be used as primary energy.
TCU temperature control model: SR-20
Model SR-20 with operating temperature range of -120~200°C, suitable reaction vessel is 100L-500L, circulating pump flow pressure is controlled at 2.4~6.6m3/h1.5bar, circulating pump control can be adjusted by frequency or fixed speed. The auxiliary heating power is 20KW, and the interface of the preheating heat exchange module is DN32.
TCU temperature control model: SR-38
Model SR-38 with operating temperature range of -120~200°C, suitable reaction vessel is 300L-1000L, circulating pump flow pressure is controlled at 5~12m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 38KW, and the interface of the preheating heat exchange module is DN40.
TCU temperature control model: SR-60
Model SR-60 with operating temperature range of -120~200°C, suitable reaction vessel is 500L-2000L, circulating pump flow pressure is controlled at 11~25m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 60KW, and the interface of the preheating heat exchange module is DN65.
TCU temperature control model: SR-95
Model SR-95 with operating temperature range of -120~200°C, suitable reaction vessel is 1000L-5000L, circulating pump flow pressure is controlled at 20~50m3/h2.5bar, circulating pump control can be adjusted by frequency or fixed speed, auxiliary The heating power is 95KW, and the interface of the preheating heat exchange module is DN80.

In addition, the energy conversion of TCU temperature control is carried out by heat exchanger and electric heating. In the temperature control mode selection, the material temperature control and jacket temperature control can be freely selected, and the material temperature control accuracy is ±1 °C. Inch / inch color touch screen. The temperature control of the whole TCU is a fully enclosed system. There is no oil mist at high temperature and no moisture in the air at low temperature. The TCU temperature control system does not increase the fluid pressure due to high temperature during operation, and automatically supplements the heat transfer medium at low temperature.
Related recommendations
-
How to Choose Chiller and Injection Moulding Machine?
1183A. First way:The 1HP water-cooled chiller can be equipped with 80 tons locking force injection moulding machine, and the temperature can be controlled at 5-10 degrees.The 1HP water-cooled chiller can be equipped with 100 tons mould-locking force i...
View details -
Semiconductor refrigeration temperature control system accessories
1133In the evaporator, since the liquid evaporates in the evaporator of the semiconductor refrigeration temperature control system, the process from liquid to gas, due to the change of the load, some of the refrigerant may not be completely evaporated...
View details -
The use and characteristics of the SUNDI series of high and low temperature cooling circulators
1302The SUNDI series of high and low temperature cooling circulators are equipment for direct or auxiliary heating in the fields of biology, physics, chemical engineering, medical treatment, environmental protection, etc. Moreover, the temperature con...
View details -
Solution to High and Low Pressure Fault of Water Cooled Chiller
1237The method to eliminate the shortcomings of high and low pressure of water-cooled chiller has always been a key point and difficulty in the industry, so it is very important to master the solutions to the shortcomings of high and low pressure of w...
View details