Performance Characteristics of 30 HP Water Cooled Chiller
The 30p water cooled chiller is an industrial water chiller with a horsepower of 30 HP. The water-cooled industrial water chiller must rely on the cooling water tower for work, while the air-cooled industrial water chiller uses its own fan for cooling, which has some requirements for the environment: for example, ventilation, humidity and temperature cannot be higher than 40 ℃, air pH value, etc.

Performance characteristics of 30p water-cooled industrial chiller:
1. The primary effect filter is set inside to ensure the heat exchange effect of the heat exchanger and prolong the service life of the heat exchanger.
2. Wide operating range, high temperature control accuracy and energy consumption saving.
3. Special microcomputer automatic control, easier operation.
4. Independent working circuit, energy saving and high efficiency.
5. Shell and tube evaporation heat exchanger is adopted, which has high efficiency, good stability, convenient maintenance and simple operation.
6. The protection function is complete, safe, reliable and durable.
7. Continuous capacity control can effectively improve the energy efficiency ratio of the unit and reduce the operation cost.
8. The product has complete specifications and wide selection range, which is suitable for all kinds of comfortable and process places.
9. Compact design, small volume, light weight, small floor area and small installation and maintenance space.
10. During operation, the load can be adjusted according to the load, and the efficiency of partial load operation is higher.
The industrial chillers independently developed and produced by our LNEYA not only have 30HP, but also have more choices. Different working conditions require different models. If you have questions or purchasing needs, please contact us at sales@lneya.com.
Related recommendations
-
Vocs condensing separation equipment expansion valve maintenance instructions
967Once the expansion valve of the vocs condensing and separating device fails, if the solution is not solved in time, the entire vocs condensing and separating device may be unavailable. Therefore, the failure of the expansion valve of the vocs cond...
View details -
Temperature control system for heating liquid to 100℃ and cooling it to 30℃
1120In terms of heating methods, common ones include steam heating, thermal oil heating, etc. Steam heating may require boilers, suitable for factories with steam supply; Thermal oil is suitable for high temperatures and requ...
View details -
Relevant knowledge of reactor refrigeration equipment
995The reactor refrigeration equipment is a kind of water cooling equipment, which is a kind of cooling water equipment that can provide constant temperature, constant flow and constant pressure. The working principle of the reactor refrigeration equ...
View details -
Small desktop sealed chiller troubleshooting solution
965Small desktop sealed chillers will have more or less failures after long-term use, so how can the compressor be solved if there are some faults? LNEYA specializes in the development and production of small desktop sealed chillers with a temperatur...
View details