Recirculating Air Control System

Recirculating Air Control System

  • Recirculating Air Control System
Recirculating Air Control System
  • Product Description
  • Knowledge Center

Description & Application:

1. Widely used in the semiconductor device for testing high and low temperature.
2. Independent refrigerated air recirculating unit.
3. Can work for a long time continuously, defrosting automatically and it can not affect the storage temperature in the process of defrosting.
4. Modular design and replace easily for standby machine,(If there are 10 sets of machines, only one standby machine is enough).
5. Solve the problems of open or close the door frequently and frosting problem in evaporation system, it will not affect the temperature of the cold storage&cryogenic box in the process of defrosting in evaporation system.
6. Easy installation (joint the box according to mechanical drawing, connect the electricity and water and set temperature completely to work).

Technical Parameters:

Model

AI-635W

AI-655W

AI-6A10W

AI-835W

AI-805W

AI-810W

Recirculating air temperature range ℃

-65℃~125℃

-65℃~125℃

-65℃~125℃

-85℃~125℃

-85℃~125℃

-85℃~125℃

Control mode

PID adaptive controller

Communication protocol

MODBUS RTU Protocol, RS 485 Interface

Temperature feedback

PT100

Input & display

7-inch color touch screen controller, temperature curve record, data export to excel format.

Temp. accuracy

±0.2℃

Heating power

3.5kW

5.5kW

10kW

3.5kW

5.5kW

10kW

Cooling  capacity

125℃

3.5kW

5.5kW

10kW

3.5kW

5.5kW

10kW

50℃

3.5kW

5.5kW

10kW

3.5kW

5.5kW

10kW

20℃

3.5kW

5.5kW

10kW

3.5kW

5.5kW

10kW

0℃

3.5kW

5.5kW

10kW

3.5kW

5.5kW

10kW

-20℃

3kW

4.2kW

7.8kW

3.5kW

5.5kW

10kW

-40℃

2.1kW

3.2kW

4.6kW

2.5kW

3.9kW

7.1kW

-55℃

0.8kW

1.2kW

2.2kW

1.6kW

2.4kW

4.2kW

-75℃




0.9kW

1.3kW

2.2kW

Circulating air flow

400m3/h

900m3/h

1300m3/h

400m3/h

900m3/h

1300m3/h

Connection size(outlet/inlet air)

DN-100

DN-100

DN-125

DN-100

DN-100

DN-125

Compressor

Scroll Copeland Compressor

Evaporator

Copper pipe aluminium fin (LNEYA)

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device,

liquid low level protection, high temperature protection and temperature fault protection.

Defrosting device

There are installed defrosting device and condensate drain inside

Continuous work

Can work continuously

Timing on & off operation

Can set a key time for starting up & stop

Refrigerant

R404A R508B

R404A R508B

R404A R508B

R404A R508B

R404A R508B

R404A R508B

Air pressure

4bar

5bar

5bar

4bar

5bar

5bar

Water-cooled W (temp.20 degree)

1200L/H

1.5bar~4bar

1800L/H

1.5bar~4bar

3200L/H

1.5bar~4bar

1600L/H

1.5bar~4bar

2600L/H

1.5bar~4bar

3400L/H

1.5bar~4bar

Product Dimension

650*750*1500

700*800*1650

700*800*1650

650*750*1500

700*800*1650

700*800*1650

Weight (water cooled)

280kg

315kg

380kg

300kg

360kg

420kg

Power

AC 380V 50HZ

7.5kW (max)

AC380V 50HZ

10.5kW (max)

AC 380V 50HZ

19kW (max)

AC380V50HZ

9kW (max)

AC380V50HZ

12kW (max)

AC380V50HZ

22kW (max)

Case material

SUS 304

SUS 304

SUS 304

SUS 304

SUS304

SUS304

How to clean air control system?

In order to respond to the requirements of the two types of society in the country, environmental protection and conservation have become increasingly important. Therefore, in order to extend the life of the product, it is still necessary to have some knowledge of maintenance, and the most important thing to maintain is to say clean. Here, Guanya Refrigeration introduces some small methods for cleaning the air cooling system:

More traditional methods are scraping and brushing. Sweep the place where you need to clean and the brush. The dirt that cannot be easily wiped off can be scraped with a sword. The second step is to use high-pressure water or chemical cleaning (mainly pickling), only to get high-pressure water or chemical water in the place where there is dirt to carry out chemical reactions, so that the dirt can be off.

However, this more traditional method does not generally clean thoroughly, and cleaning with chemical water may also cause corrosion to the equipment and damage the machine. After the chemical waste has been washed away, it will take a lot of money to process it. Therefore, cleaning agents can be used. This is also relatively environmentally friendly, safe, and thorough in cleaning. Generally, oxidation does not occur, which is beneficial to the service life of the air cooling system.
Related Products
  • LX -25℃~30℃

    LX -25℃~30℃

    April 10, 2018Single chip cleaning, printing machine, automatic clamp installation equipment, spraying equipment, ion plating equipment, etching device, single-chip processing device, slicing machine, packaging machine, the temperature of the developer management, expoview
  • Ultra-Low Temperature Cold Storage

    Ultra-Low Temperature Cold Storage

    April 11, 2018Ultra-Low Temperature Cold Storage, pharmaceutical cold storage installation, and medical cold storage construction, strictly abide by the relevant provisions of the Food and Drug Administration on medical cold storage, high quality and high standards forview
  • Explosion Proof Refrigerator -100℃~-30℃

    Explosion Proof Refrigerator -100℃~-30℃

    January 11, 2018InformationIndustrial cryogenic treatment box Industry refrigerator Industrial freezer Industrial cryogenic box Cold treatment enclosure Metal cold treatment box Industrial cooling chest Cold treatment refrigerator Cold treatment freezer Refrigeration treview
Leave a Message Email Us

we will contact you within 24 hours.

  • TEL:+ 86 510 82303782
  • FAX:+ 86 510 88587187
  • EMAIL:sales@cnzlj.com
  • ADDRESS:No.10, Zhenfa No.1 Road, Shuofang Street, New District, Wuxi, Jiangsu, China