SEARCH
Search the allChillersWater ChillerSUNDI series
Search
Hot Products
Thermoatats SUNDI Series/ TCU/KRY series/WTD seriesChillers LT series/ FL series/CDYL seriesAir Cooling Chiller Water Cooling Chiller
SEARCH
It is specially designed and developed for the characteristics of small liquid holding capacity, strong heat exchange capacity, and large pressure drop in the circulation system of the microchannel reactor.
Model | WTD-2A38W-2TE2 | WTD-4A38W-2TE2 | WTD-7A50WE2 | |||
Temperature range | -25~200°C | -25~200°C | -45~200°C | -45~200°C | -70~200°C | |
Temperature control accuracy | ±0.5℃ | |||||
Temperature resolution | 0.1K | |||||
Operation panel | Siemens 7-inch color explosion-proof touch screen | |||||
Data curve | Data curve record | |||||
Data output | U disk excel format | |||||
Temperature control accuracy | Guanya Control System Siemens PLC | |||||
System circulating fluid | 30L+30L | 30L+30L | 50L | |||
Expansion tank volume | 120L | 120L | 100L | |||
Heating power | 38KW | 38KW | 38KW | 38KW | 50KW | |
Heater | Leehom heating power 3W/cm2 | |||||
Heating actuator | Voltage regulating actuator 4~20mA control | |||||
Refrigeration ability |
200°C | 38KW | 38KW | 38KW | 38KW | 50KW |
100°C | 38KW | 38KW | 38KW | 38KW | 50KW | |
20°C | 38KW | 38KW | 38KW | 38KW | 50KW | |
-20°C | 15KW | 15KW | 20KW | 20KW | 40KW | |
-35°C | 11KW | 11KW | 25KW | |||
-60°C | 12KW | |||||
Circulating pump max | 250L/min 3bar | 250L/min 3bar | 250L/min 3bar | 250L/min 3bar | 250L/min 3bar | |
Oil interface size | DN50 PN16 | |||||
Cooling water heat exchanger | Double tube heat exchanger | |||||
Cooling water volume | 25 cubic meter/hour 1BAR~4bar max Interface size DN65 PN10 | 28 cubic meter/hour 1BAR~4bar max Interface size DN65 PN10 | 28 cubic meter/hour 1BAR~4bar max DN65 PN10 | |||
Compressor | Emerson Copeland Scroll Flexible Compressor | |||||
Temperature Sensor | PT100 Liquid temperature at inlet and outlet of each group | |||||
Refrigerant | Synthetic heat transfer oil | |||||
Refrigerant | 200L | 200L | 150L | |||
Pipe material | SUS304 | |||||
Low voltage electrical | Schneider/Siemens | |||||
Explosion-proof form | Positive pressure explosion-proof explosion-proof product installation license number: PCEC-2017-B025 | |||||
Size | 3000*2000*2200 | 3000*2000*2200 | 3000*2000*2200 | |||
Weight | 2500KG | 2600KG | 2600KG | |||
Power supply | 380V 50HZ 110KW MAX | 380V 50HZ 125KW MAX | 380V 50HZ 120KW MAX |
Cooling capacity 0.75kW~12kW Power range 1.6kW~8kW
Cooling capacity 0.4kW~6kW Power range 3kW~9kW
Cooling capacity 0.2kW~6kW Power range 3.5kW~11.5kW
Cooling capacity 0.3kW~2.1kW Power range 5.5kW~14kW
loading…
已经是到最后一篇内容了!