It is specially designed and developed for the characteristics of small liquid holding capacity, strong heat exchange capacity, and large pressure drop in the circulation system of the microchannel reactor.
Model | WTD-255-2T Dual temperature zone | WTD-455-2T Dual temperature zone | |||
Temperature range | -25°C~200°C | -45°C~250°C | |||
Temperature control accuracy | ±0.3℃ | ||||
Temperature resolution | 0.1K | ||||
Operation panel | 7 inch color touch screen | ||||
Data curve | Data curve record | ||||
Data output | U disk excel format | ||||
Control mode | Fuzzy PID adaptive controller | ||||
Communication | 9L | 9L | |||
Interface System circulating fluid |
12L | 17L built-in automatic constant temperature cooling system | |||
Expansion tank volume | 5.5kW | 5.5kW | 5.5kW | 5.5kW | |
Heating power | 5.5kW | 5.5kW | |||
Refrigeration ability |
200°C | 5.5kW | 5.5kW | 5.5kW | 5.5kW |
100°C | 5kW | 5kW | 5 kW | 5kW | |
20°C | 5kW | 5kW | 5 kW | 5kW | |
-20°C | 2 kW | 2 kW | 4 kW | 4kW | |
-35°C | 1.5kW | 1.5kW | |||
Circulating pump max | 25L/min 3bar Two way | 25L/min 3bar Two way | |||
Connection size | R3/4 Two way | R3/4 Two way | |||
Temperature Sensor | PT100 | PT100 | |||
Display 2 sets of inlet and outlet liquid temperature | Display 2 sets of inlet and outlet liquid temperature | ||||
Compressor | Emerson Copeland | Emerson Copeland | |||
Evaporator | Plate Heat Exchanger | ||||
Cooling method | Air cooling + water cooling | Air cooling + water cooling | |||
Expansion valve | Danfoss expansion valve | Danfoss expansion valve | |||
Filter drier | Danfoss | Danfoss | |||
Refrigerant | Synthetic heat transfer oil | Synthetic heat transfer oil | |||
Refrigerant | 25L | 25L | |||
Refrigerant | R404A | R404A | |||
Pipe material | SUS304 | SUS304 | |||
Ultra-high temperature cooling technology | Yes | Yes | |||
Metal insulation hose | 1.8M*4 root | 1.8M*4 root | |||
Contactor\Circuit Breaker | Schneider | Schneider | |||
Size | 700*1000*1750 Wind up | 750*1000*1750 Wind up | |||
Weight | 325KG | 365KG | |||
Power supply | 380V 50HZ 17KW MAX | 380V 50HZ 19KW MAX |
Thermal chuck or Thermal plate/Thermal control unit for ic test cooling
Cooling Power 0.6~3kW Heating Power 2~3.5kW Flow Control 12~45L/min Heat Transfer Oil Fluorinated fluid
Temperture accuracy ±0.1℃ Cooling Power 5~11kW Heating Power 2.5kW
Temperture accuracy ±0.1℃ Cooling Power 6~40kW Refrigent R410A
loading…