Temperature Control System SUNDI -90℃ ~ 250℃

Temperature Control System SUNDI -90℃ ~ 250℃

  • Temperature Control System SUNDI -90℃ ~ 250℃
  • Dynamic Temp Control Systems-2.jpg
  • Dynamic Temp Control Systems-1.jpg
Temperature Control System SUNDI -90℃ ~ 250℃


  • Product Description
  • System Introduce
  • Technical Parameter
  • Knowledge Center

-90℃~250℃
Use high temperature resistant low temperature magnetic drive pump or a leak-free high and low temperature shield-driven pump, reduce the risk of system leakage. At the same time, the system has the advantages of low noise and big traffic flow.

Model SUNDI-925W SUNDI-935W SUNDI-955W SUNDI-975W SUNDI-9A10W SUNDI-9A15W SUNDI-9A25W SUNDI-9A38W SUNDI-9A60W SUNDI-9A80W
Temp. range -90℃~+250℃(the system add pressure 3bar)
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 10 programs, each program can edit 42 steps.
Communication
Portocol
MODBUS RTU Protocol,RS485 interface
Material temp. 
feedback
PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,  reactor material temp.(external temp. sensor)
Medium temp. 
acccuracy
±0.5℃ ±1℃
Material temp. 
accuracy
±1℃
Heating power kW 2.5 3.5 5.5 7.5 10 15 25 38 60 80
Cooling 
capacity 
kW at
250℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 80
0℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 80
-40℃ 2 2.8 5 6 8 12 20 31 48 64
-60℃ 1.1 1.9 2.8 3.2 4.2 6 10 16 24 32
-80℃ 0.35 0.5 0.8 1.2 1.6 2.1 3.5 6 11 15
-85℃ 0.2 0.3 0.5 0.7 0.85 1.3 1.9 3.5 6 8
Circulation pump 
max L/min bar
20 35 50 50 110 110 150 200 400 400
2 2 2 2 2.5 2.5 2.5 2.5 2.5 2.5
Pump LNEYA magnetic drive pump German magnetic drive pump
Compressor Tecumseh closed compressor Dorin semi-closed compressor
Expansion valve Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve.
Evaporator DANFOSS/KAORI Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level 
protection, high temperature protection and temperature fault protection.
Closed circulation 
system
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure 
do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A/R23/R14 mixture,optional: R125/R23/R14 mixture
Connection size G3/4 G3/4 G3/4 G1 G1 DN32 PN10 DN32 PN10 DN40 PN10 DN50 PN10 DN50 PN10
Water-cooled 
type W(@20℃)
1100L/H
1900L/H
2400L/H
3200L/H
4000L/H
8m³/H
12m³/H
20m³/H
30m³/H
40m³/H
Dimension cm 45*85
*130
45*85
*130
55*95
*170
55*95
*170
70*100
*175
100*150
*185
205*145
*205
205*145
*205
245*145
*225
300*160
*225
Weight kg 260 295 365 570 680 950 1400 1750 2400 3150
Power 380V 50HZ 8kW 11kW 16kW 21kW 27kW 38kW 54kW 79kW 120kW 170kW


Typical application of refrigeration heating temperature control system

Dynamic thermostatic control of cold and heat source of high pressure reaction kettle, dynamic thermostatic control of double layer glass reaction kettle, and dynamic thermostatic control of cold and hot source of double-layer reactor.

Microchannel reactor thermostatic control, small temperature control system, steam - feeding system temperature control, material low temperature aging test.
The thermostatic control of the combined chemical cold source heat source, the cooling heating of the semiconductor equipment and the heating temperature of the vacuum chamber are controlled.

Advantages and functions of temperature control system of refrigeration

Temperature range from 120 to 350, performance superior, unique, high - precision, intelligent temperature control.
High cooling power from 0.5 to 1200kW, highest production stability and repeatable results.
Multi-function alarm system and safety function, use plate heat exchanger, tube type heater to increase heating and cooling rate.
7-inch and 10-inch color TFT touch screen graphics display, use magnetic drive pump, no re-seal leakage problem.
Full airtight system, extended thermal conductivity liquid life, very wide temperature range, no need to change liquid media.
Ultra-high temperature cooling technology can be cooled directly from 300 degrees of high temperature.
The principle and the function has many advantages to using staff: because only expansion of cavity in the body heat conduction medium contact with oxygen in the air (and expansion tank temperature at room temperature to 60 degrees), can achieve lower heat conduction medium absorbed by oxidation and the risk of air moisture.
No heat conduction medium evaporates at high temperature, and it can be achieved -80 ~ 190 degrees, -70 ~ 220 degrees, -88 ~ 170 degrees, -55 ~ 250 degrees, -30 ~ 300 degree continuous temperature control without pressurization.



Adopt full closed pipe design, adopt high efficiency plate heat exchanger, reduce the demand of heat conduction liquid, improve the heat utilization rate of the system, reach the rapid lifting temperature.Thermal conductive medium in a closed system, with a container, expand the heat-conducting medium not participate in circulation in the container, whether high or low temperatures, expansion tank temperature to room temperature to 60 degrees, can reduce the heat conduction medium in running the risk of absorb the moisture and volatile.

The Correct Use of the Refrigerant in the Temperature Control System

If the temperature control system has been used for more than six months, or the high and low pressure often fails, or the cooling capacity is reduced, please arrange the staff to clean the radiator.We all know that refrigerants are an essential material for the use of temperature control systems. Then do you know how much the refrigerant is suitable for the temperature control system in subzero 90 to 250?

When the temperature control system uses the pump filling machine to fill the refrigerant, it only needs to close the empty cut-off valve on the empty filling machine after the end of the pump, and the refrigerant can be filled to the refrigeration system by opening the filling valve. Under the certain amount of the filling in the cold water machine, neither too much nor too little, the small temperature control system use the quantitative filling device to fill the refrigerant by filling the refrigerant, it only needs to close the three valves after the vacuum of the refrigerating device and stop the vacuum pump, and dismantle the joint of the pressure resistant rubber tube connected with the vacuum pump and install it in the quantitative filling device. Open the liquid outlet valve and drain the air in the hose, then tighten the connector of the hose to check whether it leaks.

When the refrigerant of the temperature control system is filled with the refrigerant, read the pressure gauge on the filling device at the very first, the rotate the scale sleeve, and the quantitative liquid line corresponding to the pressure gauge is found on the sleeve, and the initial level of the liquid surface of the refrigerant in the glass tube is recorded. Then open the three-way valve, the refrigerant enters the refrigeration system through the hose, and the liquid level of the refrigerant in the glass tube begins to decrease. When the required amount of filling is achieved, close the discharge chamber and the three links on the charging device and the charging operation end.

The temperature control system is used in many fields. Plastic, electronic. Electroplate。 Laser, food, textile, chemical industry. Packing。 Medical care。 Even in industries such as test and even beverage, the industrial refrigeration equipment and temperature control system group play a very important role in beer production line.
Related Products
  • Direct-Cooled Ultra-Low Temperature Chiller -150℃

    Direct-Cooled Ultra-Low Temperature Chiller -150℃

    January 11, 2018Temperature ranges from - 5 ~ - 150 degrees, can meet different temperature; Adopt environmental protection refrigerants; Famous brand semi-closed piston compressor, semi-closed bipolar piston compressor, semi-hermetic screw compressor, main brand are BOCK.view
  • High-Low Temp. Test Chamber

    High-Low Temp. Test Chamber

    March 30, 2018Performance characteristics:1. In the refrigeration system, the condensation adopts air cooling mode, which has a wide temperature control range, which can meet the user's various needs.2. With a unique b...view
  • High-Low Temp. Humidity Test Chamber

    High-Low Temp. Humidity Test Chamber

    April 8, 2018Performance characteristics: 1. With wide temperature control range, can meet the user's various needs.2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control canview
Leave a Message Email Us

we will contact you within 24 hours.

  • TEL:+ 86 510 82303782
  • FAX:+ 86 510 88587187
  • EMAIL:sales@cnzlj.com
  • ADDRESS:No.203, Hongyun Road, Hongshan Street, Optoelectronics Park, Xinwu District, Wuxi City, Jiangsu Province,China