Low-temperature refrigerator manufacturers’ energy adjustment instructions
The energy regulation of low-temperature refrigerator manufacturers’ equipment during operation is also very important. In order to adapt to the change of energy load, Wuxi Guanya (LNEYA) low-temperature refrigerator manufacturers should pay attention to the energy regulation process.
In order to adapt to the load change of the refrigeration system during the operation of the low-temperature refrigerator manufacturer, the water temperature of the unit still needs to maintain its constant requirements, and the manufacturer will effectively accomplish this task through its energy adjustment. The control system of the -150 low temperature refrigerator manufacturer needs to first detect the water temperature of the unit, compare it with the set value, and then issue an energy adjustment command, which will increase or decrease the cooling capacity of the unit to a certain extent.
The manufacturer and the piston refrigeration compressor are the same. The adjustment of the energy of the equipment during the operation is also effective to adjust the cooling capacity by adjusting the displacement, and the energy of the compressor is mainly used during the operation. Adjustment mechanism to achieve.
The energy adjustment of the manufacturer’s multi-head unit can also be realized directly by increasing or decreasing the number of compressors running. The control program can set the loading sequence of each compressor. Therefore, multi-head low temperature refrigerator manufacturers are more widely used in engineering practice due to their excellent partial load performance. The manufacturer’s compact structure, stable operation, stepless adjustment of cooling capacity, good energy saving and less wearing parts.
The equipment of Wuxi Guanya (LNEYA) low-temperature refrigerator manufacturers is compact in structure and efficient in operation, saving resources to a certain extent.

Related recommendations
-
Various reactors and materials use PLC temperature control system
1001The PLC temperature control system is used for the lifting and constant temperature control of glass reactors, metal reactors and bioreactors, especially for heat exothermic control in the reaction process. The heat transfer oil in the jacket of t...
View details -
Laboratory dedicated chiller pressure description
905The laboratory-specific chiller is one of the more popular equipments in the mechanical equipment industry. For this reason, the relevant pressure instructions have been specially compiled to help you better understand the laboratory-specific chil...
View details -
Description of heat sink characteristics in chip temperature control
1109With the continuous development of electronic chips, its heat dissipation technology is also advancing. LNEYA chip temperature control technology is continuously promoted along with chip test equipment. The development trend of modern computer chi...
View details -
The Introductions of the Ultra Low Temperature Recirculating Chillers
961The performances of ultra low temperature recirculating chillers are different because of their different compressors. Compared with piston compressor, the structure of screw-type compressor tends to be more precise, so when users need to select u...
View details