How to Solve the Problem of Compressor Noise in Industrial Low Temperature Chiller?
In industrial low temperature chiller, compressor operation will produce noise, but only the
difference of sound size. Generally speaking, there will be some problems if the noise is too large. So, how to solve the problem of compressor noise?
Generally speaking, compressor noise must first understand the causes of its noise, in order to better deal with. The main reasons are: the compressor is not fixed well; compressor quality problems; compressor load is too large; compressor power supply is abnormal, running time is too long and other reasons. Understanding these reasons and solutions can make better use of industrial low temperature chiller compressors.
For the industrial low temperature chiller that have just started to use, if the noise is too big, it may be caused by the compressor not fixed properly when it is assembled. The fixing of the industrial low temperature chiller is fixed on the chiller bracket by the compressor foot. It must be fixed properly to ensure the normal operation noise of the compressor of the industrial cryogenic water chillers.
If it is not the fixed problem of compressor, it may be the compressor quality problem of industrial low temperature chiller. In the production of industrial low temperature chiller, Wuxi Guanya adopts brand compressor, which guarantees a little more quality.
If it is not fixed and quality problems, it may also be that the compressor load is too large, which will also restrict the operation of the compressor. The compressor load is too large is the larger reason for the compressor running noise. When the load rate exceeds 80%, there will be various problems.
If the power supply of industrial low temperature chiller is not normal, if the current and voltage are not working properly, noise will be produced. Only the normal current can ensure the normal operation of the compressor of industrial low temperature chiller.
Another point is that the long running time of industrial low temperature chiller will also affect the life of their compressors. The wear and tear of internal bearings or axle boxes of industrial low temperature chiller will cause greater noise of compressors. It is suggested that the compressors should be replaced or maintained.
Industrial low temperature chiller is widely used in industry, so the above failures should be solved in time to avoid affecting the production process of users.
Related recommendations
-
Lneya’s high and low temperature cooling circulator instructions
599The high and low temperature cooling circulator is developed and produced by LNEYA using its refrigeration and heating temperature control technology. When using high and low temperature cooling circulators, users are advised to use them according...
View details -
Cold and hot shock constant temperature and humidity test chamber operation steps
551When selecting the appropriate model of the LNEYA hot and cold shock constant temperature and humidity test chamber, you need to pay attention to the operation and installation steps. The user needs to be well prepared for the installation work. T...
View details -
Application of gas cooling temperature control system in optical module
496The gas cooling temperature control system has a wide range of temperatures and can be widely used to meet the requirements of more production and engineering environments. It is applicable to reliability tests such as chip, microelectronic devi...
View details -
Why do constant temperature and humidity chamber need water cooling units?
404Constant temperature and humidity chamber need water cooling units mainly for the following key reasons: Accurate temperature and humidity control: Water cooling units can provide efficient and accurate temperature regulation capabilit...
View details