The Noise Analysis of Precision Chiller
Generally speaking, even the most sophisticated refrigerating equipment will also have some trouble when used for a long time. If the noises present in the precision chiller after prolonged use, I am sure that it appears some faults. So let’s go deeper to see where these noises are from.
The noise of compressor
The compressor is in the core position of the inner structure of the precision chiller. In general, compressors include screw and stroll, you can pick up one as what you need. Once the compressor has some noise, the first thing you should do is to check out if the expansive valve is open excessively; if so, you ought to adjust it. Next, you should see if the freezing medium is overmuch; if so, you had better remove the needless refrigerators.
The noise of water pump
It is attributable to the water quality mainly if the water pump has some noises. I suggest that water treatment should proceed according to the requirement of the chillers.
The accessories lack lubricant
The configuration of most of chillers is made of metal. Once the accessories are short of lubricant, the frictions can not be avoided, making some noises. Besides, you have to keep maintenance in daily life to reduce the rate of faults.
Oil starvation because of overload
You can find out whether the compressor is fuel elan when there are some noises. If it is, you can refuel it. To check if the compressor is overloaded will help you solve it in time.
Through the introduction of precision chillers, you must have a better understanding. If you are eager to further study, you can follow Guanya Refigeration Technology Co., Ltd.
Related recommendations
-
What Are the Commonly Used Refrigerants For Brand Selection of Refrigerating Chillers?
1087When the enterprise chooses the refrigerant in the cryo chillers unit brand, what should it need to pay attention to the present market commonly used refrigerant? What is the difference between specific refrigerant properties? Take a look at the b...
View details -
What is the temperature control method of the reactor?
884The reaction kettle used for temperature control has a large capacity and a thick wall, so it is a controlled object with a large heat capacity and a long pure lag time. As the reaction progresses, the heat transfer coefficient of each heat transf...
View details -
Vocs gas condensing treatment equipment compressor maintenance instructions
955The vocs gas condensing treatment equipment is an important equipment in the process of exhaust gas treatment. Among them, the compressor is one of the main components, and its performance is affecting the operating efficiency of the entire vocs g...
View details -