Relationship Between Poor Refrigeration Performance And Refrigerant In Low Temperature Industrial
The effect of the refrigeration system of the low-temperature industrial refrigerator is directly related to the refrigerant. Once the refrigerant leaks, the cooling capacity will be insufficient, so that the suction and exhaust pressures are relatively low, and the expansion valve and the evaporator are in operation. The balance pressure cannot be maintained. Therefore, if the refrigerant leaks from the low-temperature industrial refrigerator (group) is found, it is not rushed to fill the system with the refrigerant. Instead, the leak point should be immediately found and the refrigerant should be filled after repair.
In the refrigeration system of the low-temperature industrial refrigerator (group), pay attention to the amount of refrigerant, too little, too much, too much, too much may cause the exhaust pressure of the low-temperature industrial refrigerator to rise, higher than the normal value, need to stop in time, use High pressure exhaust removes excess refrigerant from the system.
If the low-temperature industrial refrigerator (group) is filled with too much refrigerant after maintenance, the cooling effect will be worse, because the charge of the refrigerant will occupy a part of the condenser of the low-temperature industrial refrigerator (group), which is reduced. The cooling area and cooling efficiency are also decreasing, and the cooling rate is continuously decreasing. Therefore, according to the operation sequence, after the machine is shut down for a few minutes, excess refrigerant is released at the high pressure shut-off valve, and the residual air in the system can be released at the same time.
Of course, the refrigeration system inside the low-temperature industrial refrigerator (group) also needs to pay attention to, once the air in the low-temperature industrial freezer (group) refrigeration system will reduce the cooling efficiency, this time can be several times after a few minutes after the shutdown The high pressure shut-off valve releases air, and it is also possible to properly fill some refrigerant according to the actual situation.
The refrigeration effect of the low-temperature industrial refrigerator (group) is closely related to the amount of refrigerant. Therefore, users should pay attention to the refrigeration effect in time and strive for better operation of the low-temperature industrial refrigerator (group).
Related recommendations
-
What are the power test systems for new energy car batteries?
938The LNEYA power battery system is tested for battery testing of new energy vehicles, but modern new energy vehicles have many types of batteries. So what are the characteristics? The ternary lithium battery refers to a lithium battery in which the...
View details -
Cooling fin cleaning instructions for 20 freezers
1179As one of the main accessories of the 20-piece freezer, the heat-dissipating fins are very important. Therefore, the cleaning of the heat-dissipating fins is also very important. How to clean them? The fins of the freezer are also called finned co...
View details -
What are the price factors affecting 60P freezers?
1119When users choose 60P freezers, they are very concerned about the price. Then the factors affecting the price, Wuxi Guanya (LNEYA) need to make everyone understand. The freezer brand is an important intangible asset of a company or product, and is...
View details -
Why do chemical raw materials require low-temperature chillers?
873The main reasons for using low-temperature chillers in the production process of chemical raw materials are as follows: Temperature control: Many chemical reactions are temperature sensitive and require precise temperature control to...
View details