Refrigeration heating circulator list resonance fault description
Refrigeration heating circulator leaderboard works:
When the temperature of the reactor, reactor, rotary evaporator, extraction equipment, etc. of the refrigeration heating circulator needs to be rapidly increased or lowered, the equipment can quickly reach the set temperature.
LNEYA’s refrigeration and heating circulator list adopts a fully enclosed circulation system to avoid high temperature oil mist odor and low temperature absorption of moisture, which ensures that the working environment will not have a pungent odor, and also avoids the heat transfer medium absorbing moisture. Viscous adhesion to the reactor wall results in poor heat transfer. The heating and cooling of the equipment can be quickly converted, and the medium used (heat-conducting oil) is the same medium, which improves the disadvantages of the two different instruments required for heating and cooling.
Fixing parts of the cooling and heating circulator list cause resonance reasons:
The professional manufacturer of the refrigeration and heating circulator list tells the enterprise that if the resonance is encountered, the cement foundation may be too light or the grouting is poor or the plane size is too small, causing the fan foundation to be out of contact with the foundation, the anchor bolts are loose, and the base connection is not strong. The foundation stiffness is not enough or the stiffness of the fan base or the volute is too low, the inlet and outlet pipes connected to the fan are unsupported and softly connected, the adjacent facilities are too close to the foundation of the fan, or the stiffness is too small. In general, professional high and low temperature manufacturers recommend that you can reinforce the foundation or re-grout, tighten the nut, strengthen its stiffness or add support and soft joints, and even increase the stiffness.
In fact, reliable manufacturers on the cooling and heating cycler list can provide good quality and reduce the occurrence of faults.
Related recommendations
-
Application of gas cooling temperature control system in optical module
1085The gas cooling temperature control system has a wide range of temperatures and can be widely used to meet the requirements of more production and engineering environments. It is applicable to reliability tests such as chip, microelectronic devi...
View details -
Cooling heating system adds temperature solution for pharmaceutical and chemical industry
1026LNEYA is a professional manufacturer of various temperature control instruments for more than ten years. It is involved in the pharmaceutical, chemical, scientific research, industrial, new energy, chip and other industries. The research and devel...
View details -
Why does a glass reactor require a circulating chiller and heater?
865The common glass reaction vessels on the market can be divided into three categories: negative pressure glass reaction vessels, vacuum glass reaction vessels, and high-temperature and high-pressure stirred glass reaction vessels. The g...
View details -
Low temperature chilled lubricant selection considerations
1319When you use a cryogenic chilled, you definitely want to know about all aspects of the cryocooler. But one of the things that needs everyone's attention is that the type of lubricant for the chilled is chosen because there are many influencing fac...
View details