Attention points for daily inspection of low temperature control equipment at minus 30℃
The low temperature control equipment at minus 30 degrees Celsius is a refrigeration unit or also called a refrigeration unit. The difference from the chiller is the temperature range. It is a commonly used low-temperature equipment in the industry and needs to operate for a long time. So what points should be paid attention to in daily inspection during operation?

1. Power supply part inspection
Before installation, the low temperature control equipment of minus 30 degrees Celsius will make a plan for the surrounding installation environment, circuit and power supply. If the conditions and standards are suitable, the installation will be carried out, and the installation will be re-planned if the conditions are not suitable. After a long period of use, check the power supply part to see if the power supply accessories are damaged, whether the wires inside and outside the equipment are aging, and whether there is damage. If there are problems, check and correct them in time.
2. Refrigerant inspection
The refrigeration effect in the low temperature control equipment of minus 30 degrees Celsius is a more critical part. If the refrigerant leaks, it will affect the refrigeration temperature, fail to achieve the expected refrigeration effect, and affect the overall work progress. While checking the refrigerant of the low temperature control equipment at minus 30 degrees Celsius, check whether the joints of the relevant parts are loose or cracked. If there is a problem, solve it quickly to avoid refrigerant leakage. If a refrigerant leak is found, it needs to be supplemented, and it needs to be added in accordance with relevant standards.
3. Pipeline inspection
The low temperature control equipment of minus 30 degrees Celsius needs to be inspected after a certain period of time to see if there is any leakage. If a leak is found, it needs to be repaired, and then used after checking that there is no leakage.
Related recommendations
-
Operating Instructions For the Low Temperature Test Chamber
1187The low temperature test chamber is a necessary test equipment in aviation, automobile, household appliances, scientific research and other fields. It is used to test and determine the parameters and performance of electrical, electronic and other...
View details -
Working Principle and Process of Chiller Temperature Control and Pressure Controller
1670Air cooled chiller temperature controller is a two - position regulator, also known as chiller temperature control relay.According to the change of adjusted temperature,the chiller temperature control makes the contact on or off, thus controlling ...
View details -
Debugging steps of industrial water chiller in chemical industry
954After completing the installation of industrial water chillers in chemical enterprises, certain debugging needs to be carried out in the early stage of operation. Only through careful debugging can we find out whether there are hidden troubles in...
View details -
Performance Characteristics of 30 HP Water Cooled Chiller
1137The 30p water cooled chiller is an industrial water chiller with a horsepower of 30 HP. The water-cooled industrial water chiller must rely on the cooling water tower for work, while the air-cooled industrial water chiller uses its own fan for coo...
View details